LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 290 of 463
Command Syntax
[SOURce:]STEP:FREQuency[:INITial] <nr2 >, <cr>
Description
This command sets the initial STEP frequency.
Parameters
Frequency, < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
STEP:FREQ 50.0, SAT
Query Format
[SOURce:]STEP:FREQuency[:INITial]?
Returned Data Format
<nr2>
Query Example
STEP:FREQ?
50.0000
Query Syntax
[SOURce:]STEP:FREQuency[:INITial]:MINimum?
Description
This command returns the minimum permissible set value for the
initial STEP frequency.
Returned Data Format
<nr2>
Query Example
STEP:FREQ:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
Query Syntax
[SOURce:]STEP:FREQuency[:INITial]:MAXimum?
Description
This command returns the maximum permissible set value for the
initial STEP frequency.
Returned Data Format
<nr2>
Query Example
STEP:FREQ:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
Query Syntax
[SOURce:]STEP:FREQuency[:INITial]:DEFault?
Description
This command returns the default set value for the initial STEP
frequency.
Returned Data Format
<nr2>
Query Example
STEP:FREQ:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
Command Syntax
[SOURce:]STEP:FREQuency:FINal <nr2 >, <cr>
Description
This command sets the final STEP frequency.
Parameters
Frequency, < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
STEP:FREQ:FIN 55.0, SAT
Query Format
[SOURce:]STEP:FREQuency:FINal?
Returned Data Format
<nr2>
Query Example
STEP:FREQ:FIN?
55.0000