LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 237 of 463
8.6.3
Transient Segments Commands
The following commands may be used to control stored transient program executions.
Command Syntax
PROGram:TRANsient
Description
This command controls transient execution
Parameters
RUN | STOP | PAUSe | STEP | RESTart
Parameter Format
<cr>
Example
PROG:TRAN RUN
Query Format
PROGram:TRANsient?
Description
Query format returns the transient execution state as either RUN,
STOP, PAUS, STEP or REST
Returned Data Format
<cr>
Query Example
PROG:TRAN?
RUN
Command Syntax
PROGram:TRANsient:AUTORMS <BOOLEAN>
Description
If enabled, the value of any waveform used in a transient segment is
normalized in order to match the RMS set point.
If disabled, the waveform is reproduced without any normalization.
This function is useful for waveform substitution at the steady state
level.
Note:
This function is related to the AUTORMS function in the steady
state segment.
Parameters
[ 0 | OFF | 1 | ON ]
Parameter Format
<b>
Example
PROG:TRAN:AUTORMS 1
Query Format
PROGram:TRANsient:AUTORMS?
Returned Data Format
<b>
Query Example
PROG:TRAN:AUTORMS?
1
Command Syntax
PROGram:TRANsient:CR <BOOLEAN>
Description
This command enables or disables the Cycle Reset mode during
transient execution. When on, Cycle Reset will resync each transient
run in repeat mode to the start phase angle.
Parameters
[ 0 | OFF | 1 | ON ]
Parameter Format
<b>
Example
PROG:TRAN:CR 1
Query Format
PROGram:TRANsient:CR?
Returned Data Format
<nr1>
Query Example
PROG:TRAN:CR?
0