Query Format
MEASure:SPECTrum:OHD?
Description
Returns Odd Harmonic Distortion of the most recent
:MEASure:SPECTrum:parameter
command
Returned Data Format
<nr2>
Query Example
MEAS:SPECT:OHD?
3.5690
Query Format
MEASure:SPECTrum:VOLTage#:OHD?
Description
Same as “MEAS:SPECTrum:OHD?” but selects voltage and phase
#.Returns Odd Harmonic Distortion of the selected phase voltage.
Returned Data Format
<nr2>
Query Example
MEAS:SPECT:VOLT1:OHD?
10.5891
Query Format
MEASure:SPECTrum:VLL#:OHD?
Description
Same as “MEAS:SPECTrum:OHD?” but selects Line to Line voltage
#.Returns Odd Harmonic Distortion of the selected Line to Line
voltage.
Returned Data Format
<nr2>
Query Example
MEAS:SPECT:VOLT1:OHD?
10.5891
Query Format
MEASure:SPECTrum:CURRent#:OHD?
Description
Same as “MEAS:SPECTrum:OHD?” but selects current and phase
#.Returns Odd Harmonic Distortion of the selected phase currebt.
Returned Data Format
<nr2>
Query Example
MEAS:SPECT:CURR1:OHD?
22.5948