61
CHAPTER 3 SPECIFICATIONS
3
3.
7
List
s of
R
e
mot
e
B
u
ffer
Mem
o
ry
Areas
280 (118H)
CH1
Stop mode
setting
Stop mode
setting
Stop mode
setting
1
R/W
281 (119H)
CH1
Automatic
backup
setting after
auto tuning of
PID constants
Automatic
backup
setting after
auto tuning of
PID constants
Automatic
backup
setting after
auto tuning of
PID constants
0
R/W
282 to
303(11AH
to 12FH)
System area
System area
System area
304 (130H)
CH2
Input range
Input range
Input range
2(TT)
7(RT)
R/W
305 (131H)
CH2
Set value
(SV) setting
Set value
(SV) setting
Set value
(SV) setting
0
R/W
306 (132H)
CH2
Proportional
band (P)
setting
Heating
proportional
band (Ph)
setting
Heating
proportional
band (Ph)
setting
30
R/W
307 (133H)
CH2
Integral time
(I) setting
Integral time
(I) setting
Integral time
(I) setting
240
R/W
308 (134H)
CH2
Derivative
time (D)
setting
Derivative
time (D)
setting
Derivative
time (D)
setting
60
R/W
309 (135H)
CH2
Upper limit
output limiter
Heating
upper limit
output limiter
Heating
upper limit
output
limiter
1000
R/W
310 (136H)
CH2
Lower limit
output limiter
System area
System area
0
R/W
311 (137H)
CH2
Output
variation
limiter setting
Output
variation
limiter setting
Output
variation
limiter
setting
0
R/W
312 (138H)
CH2
Setting
change rate
limiter/Setting
change rate
limiter
(temperature
rise)
Setting
change rate
limiter/Setting
change rate
limiter
(temperature
rise)
Setting
change rate
limiter/Setting
change rate
limiter
(temperature
rise)
0
R/W
313 (139H)
CH2
Setting
change rate
limiter unit
time setting
Setting
change rate
limiter unit
time setting
Setting
change rate
limiter unit
time setting
0
R/W
314(13AH)
CH2
Upper limit
setting limiter
Upper limit
setting limiter
Upper limit
setting
limiter
1300(TT)
6000(RT)
R/W
315(13BH)
CH2
Lower limit
setting limiter
Lower limit
setting limiter
Lower limit
setting
limiter
0(TT)
-2000(RT)
R/W
Address
(decimal
(hexa-
decimal))
Target
channel
Setting contents
Default
value
*1
Read/
Write
*2
Auto-
matic
setting
*3
Non-
volatile
memory
write
avail-
ability
*4
Change
of
setting
during
opera-
tion
*5
Change
of setting
when all
channels
stop
*6
Reference
Standard
control
Heating-
cooling
control
Mix control
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......