For the NZ2GF2B-60TCTT4, "Setting Range" is already set to -2000 to 32000, which is the lower limit value of the
setting range for Input range (Input range: 7, 10, 20, 29, 41) and the upper limit value (Input range: 205) (For the
NZ2GF2B-60TCRT4, the lower limit value is -3000). When actually set the values, enter the values within the setting
range for Input range.
*2
"Setting Range" is already set to -32000 to 32000, which is the lower limit value of the setting range (Input range: 205)
and the upper limit value (Input range: 205). When actually set the values, enter the values within the setting range of
the set alert mode.
*3
"Setting Range" is already set to -32000 to 32000, which is the full scale lower limit value for Input range (Input range:
205) and the full scale upper limit value (Input range: 205). When actually set the values, enter the values within the full
scale range for Input range.
*4
"Setting Range" is already set to 0 to 32000. 32000 is the full scale upper limit value for Input range (Input range: 205).
When actually set the values, enter the values within the full scale range for Input range.
Warning error control
Warning non-inductive belt setting
Warning delay count
Temperature rise completion setting
Temperature rise completion range setting
Temperature rise completion soak time setting
Sensor correction function selection
CH
Sensor correction function selection
Peak current control function
CH
Peak current restrain control_divide group setting
AT loop disconnection detection function
CH
AT loop disconnection detection function enable_disable setting
Manipulated value resolution switching for output with another analog module
Cold junction temperature compensation selection
Transistor output monitor ON delay time setting
CH
Scaling function
CH
Measured value_PV_scaling function_enable_disable setting
CH
Measured value_PV_scaling lower limit value
CH
Measured value_PV_scaling upper limit value
CH
Warning setting
CH
Mode setting of warning 1
CH
Mode setting of warning 2
CH
Mode setting of warning 3
CH
Mode setting of warning 4
CH
Warning setting value 1
CH
Warning setting value 2
CH
Warning setting value 3
CH
Warning setting value 4
Sensor correction value setting
CH
Sensor correction value setting
CH
Auto tuning setting
CH
Auto tuning mode selection
CH
AT bias
Self tuning setting
CH
Self tuning setting
CH
Simultaneous temperature rise
function setting
CH
Simultaneous temperature rise group setting
CH
Simultaneous temperature rise lean data
CH
Simultaneous temperature rise waste time
CH
Simultaneous temperature rise AT mode selection
Setting item
Reference
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......