34
3.2
Performance Specifications
Item
Specifications
NZ2GF2B-60TCTT4
NZ2GF2B-60TCRT4
Control output
Transistor output
Number of temperature input points
4 channels/module
Type of usable temperature sensors, the temperature
measurement range, the resolution, and the effect from wiring
resistance of 1
Accuracy
Indication accuracy
Ambient temperature:
25
5
Full scale
(
0.3%)
Ambient temperature: 0
to 5
Full scale
(
0.7%)
Cold junction
temperature
compensation
accuracy (ambient
temperature: 0
to
55
)
Temperature process value
(PV): -100
or more
Within
1.0
Temperature process value
(PV): -150
to -100
Within
2.0
Temperature process value
(PV): -200
to -150
Within
3.0
Sampling cycle
250ms/4 channels
500ms/4 channels
Control output cycle
0.5 to 100.0s
Input impedance
1M
Input filter
0 to 100s (0: Input filter OFF)
Sensor correction value setting
-50.00 to 50.00%
Operation at sensor input disconnection
Upscale processing
Temperature control method
PID ON/OFF pulse or two-position control
PID constants range
PID constants setting
Can be set by auto tuning.
Proportional band (P)
0.0 to 1000.0% (0: Two-position control)
Integral time (I)
0 to 3600s (set 0 for P control and PD control.)
Derivative time (D)
0 to 3600s (set 0 for P control and PI control.)
Set value (SV) setting range
Within the temperature range set in the thermocouple/platinum resistance thermometer to
be used
Dead band setting range
0.1 to 10.0%
Transistor
output
Output signal
ON/OFF pulse
Rated load voltage
10 to 30VDC
Max. load current
0.1A/point, 0.4A/common
Max. inrush current
0.4A 10ms
Leakage current at OFF
0.1mA or less
Max. voltage drop at ON
1.0VDC (TYP) at 0.1A 2.5VDC (MAX) at 0.1A
Response time
OFF
ON: 2ms or less, ON
OFF: 2ms or less
Number of accesses to non-volatile memory
Max. 10
12
times
Isolation method
Between all power supply and communication system input terminals and all input
terminals: Transformer isolation and digital isolator isolation
Between input channels: Transformer isolation and digital isolator isolation
Between all power supply and communication system terminals and all output terminals:
Photocoupler isolation
Withstand voltage
Between all power supply and communication system terminals and all input terminals:
500VAC for 1 minute
Between input channels: 500VAC for 1 minute
Between all power supply and communication system terminals and all output terminals:
500VAC for 1 minute
Noise immunity
Noise voltage 500Vp-p, noise width 1
s, noise frequency 25 to 60Hz (noise simulator
condition)
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......