Probes and Biopsy 13-49
b) Introduce a needle into the cap, and ensure that the needle tip contacts the bottom of the
needle cap.
c) Hold the needle for 1 or 2 seconds and then withdraw it quickly from the magnetizer.
NOTE: if the needle cap associated with the needle does not meet the requirements, you are
recommended to use BBraun Sterican < 35mm needles cap or B&D Microlance < 35mm
needles cap.
13.4.5 Procedure
NOTE:
1. The Pan Zoom function is not supported on eSpacial Navi mode.
2. Do not freeze the ultrasound image during the procedure. Otherwise, biopsy
guidance information will disappear.
3. When the insertion angle of a needle relative to the skin surface exceeds 60°,
is displayed at the right side of
on screen to notify users to adjust the angle.
After the angle is smaller than 60°,
disappears.
Perform the following steps.
1. Hold the probe stably and put the needle close to the probe for connection. After the needle
and probe are successfully connected, the system automatically calculate the maximum depth
at which the needle can be detected in real time, and display the depth value in the touch
screen.
NOTE: when the actual depth is greater than the maximum value, the needle guidance
information disappears temporally.
Adjust the needle position and angle to define the position for inserting the needle. Pay attention to
the field strength during the needle guidance process.
Содержание TE5
Страница 1: ...TE7 TE5 Diagnostic Ultrasound System Operator s Manual Basic Volume ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ......
Страница 36: ......
Страница 54: ......
Страница 56: ...4 2 Exam Preparation 4 1 1 New Patient Information The Patient Info screen is shown as follows 2 1 3 ...
Страница 110: ......
Страница 115: ...Display Cine Review 6 5 6 Tap Return on the screen or tap Freeze to exit image compare ...
Страница 120: ......
Страница 124: ......
Страница 156: ......
Страница 174: ......
Страница 192: ...12 18 Setup Select Advanced and do as follows Select MAPS and do as follows ...
Страница 202: ...13 2 Probes and Biopsy C5 2s L12 4s L7 3s P4 2s L14 6s C11 3s L14 6Ns V11 3Ws P7 3Ts 7LT4s ...
Страница 203: ...Probes and Biopsy 13 3 7L4s P10 4s L20 5s P7 3s L14 5sp SC6 1s SP5 1s 6CV1s L9 3s C5 1s L11 3VNs C4 1s ...
Страница 222: ...13 22 Probes and Biopsy No Name Description 8 Grooves of the needle guided bracket Matched with the tabs of the probe ...
Страница 226: ...13 26 Probes and Biopsy NGB 034 NGB 035 ...
Страница 250: ......
Страница 272: ......
Страница 276: ...A 4 Wireless LAN Tap Add Manually create a network profile to set ...
Страница 282: ......
Страница 318: ......
Страница 322: ......
Страница 323: ...P N 046 006959 07 1 0 ...