Image Optimization 5-39
A, B and C sectional images correspond to the following sections of the 3D image.
Section A: corresponds to the 2D image in B mode. Section A is the sagittal section, as
shown in Figure A above.
Section B: is the horizontal section, as shown in Figure B above.
Section C: is the coronal section, as shown in Figure C above.
CAUTION:
Ultrasound images are provided for reference only, not for confirming
diagnoses. Use caution to avoid misdiagnosis.
NOTE:
In accordance with the ALARA (As Low As Reasonably Achievable) principle, try to
shorten the sweeping time after a good 3D image is obtained.
5.11.2 Smart 3D
The operator manually moves the probe to change its position/angle when performing the scan.
After scanning, the system carries out image rendering automatically, then displays a frame of the
3D image.
Smart 3D is an option.
Only probe L12-4s and L14-6Ns support Smart 3D imaging.
NOTE:
In Smart 3D image scanning, if the probe orientation mark is oriented to the operator’s
finger, perform the scan from right to left in linear scan, or rotate the probe from left to
right in rocked scanning. Otherwise, the VR direction will be wrong.
5.11.2.1 Basic Procedures for Smart 3D Imaging
To perform Smart 3D imaging:
1. Select the appropriate probe and exam mode. Make sure there is sufficient gel on the probe
for scanning.
2. Obtain a 2D image.
3. Tap [Smart 3D] on the right side of the operating panel to enter Smart 3D acquisition
preparation mode, and define the ROI as well as the curved VOI.
To adjust the ROI:
Содержание TE5
Страница 1: ...TE7 TE5 Diagnostic Ultrasound System Operator s Manual Basic Volume ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ......
Страница 36: ......
Страница 54: ......
Страница 56: ...4 2 Exam Preparation 4 1 1 New Patient Information The Patient Info screen is shown as follows 2 1 3 ...
Страница 110: ......
Страница 115: ...Display Cine Review 6 5 6 Tap Return on the screen or tap Freeze to exit image compare ...
Страница 120: ......
Страница 124: ......
Страница 156: ......
Страница 174: ......
Страница 192: ...12 18 Setup Select Advanced and do as follows Select MAPS and do as follows ...
Страница 202: ...13 2 Probes and Biopsy C5 2s L12 4s L7 3s P4 2s L14 6s C11 3s L14 6Ns V11 3Ws P7 3Ts 7LT4s ...
Страница 203: ...Probes and Biopsy 13 3 7L4s P10 4s L20 5s P7 3s L14 5sp SC6 1s SP5 1s 6CV1s L9 3s C5 1s L11 3VNs C4 1s ...
Страница 222: ...13 22 Probes and Biopsy No Name Description 8 Grooves of the needle guided bracket Matched with the tabs of the probe ...
Страница 226: ...13 26 Probes and Biopsy NGB 034 NGB 035 ...
Страница 250: ......
Страница 272: ......
Страница 276: ...A 4 Wireless LAN Tap Add Manually create a network profile to set ...
Страница 282: ......
Страница 318: ......
Страница 322: ......
Страница 323: ...P N 046 006959 07 1 0 ...