13-48 Probes and Biopsy
Controls are as follows:
Item
Description
Needles
Select the desired needle from the drop-down list.
You can set the most frequently used needle to a
favorite one. For example, after selecting a needle,
turns into
, which indicates that the selected needle
becomes a favorite one.
Display Favourite
Only
After it is ticked, only the favorite needles are displayed
on the needles list.
Auto Optimize
After it is ticked, the system adjusts focus position
automatically according to the position of the needle tip,
and enable or disable ExFOV function.
eS.Navi Settings Menu
Tap [eS.Navi] → [Image] → [eS.Navi Settings] to enter the eS.Navi Settings menu, and tick the
items to be displayed on the screen.
13.4.4 Preparation before Needle Guidance
1. Scan the target tissue and adjust the image parameters.
2. Check the field strength to ensure that the filed strength indicator is
. If the filed strength is
low, hold the probe and tap [Calibrate] on [NEEDLE] menu. Do not move the probe during the
calibration.
Indicator Colors
Description
Green
Low magnetic interference: appropriate for needle guidance;
Yellow
Medium magnetic interference: be cautious for needle guidance;
Red
High magnetic interference: do not perform needle guidance.
NOTE: before and during calibration, keep the probe away from the magnetic sources, such
as metal objects, electrical motors, switching power supplies, nerve stimulators and similar
medical devices.
3. Magnetize a needle cap.
a) Place an appropriate sterile needle cap (length: 3.5cm to 4.5cm, diameter <7mm, with
bottom closed) into the magnetizer.
Содержание TE5
Страница 1: ...TE7 TE5 Diagnostic Ultrasound System Operator s Manual Basic Volume ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ......
Страница 36: ......
Страница 54: ......
Страница 56: ...4 2 Exam Preparation 4 1 1 New Patient Information The Patient Info screen is shown as follows 2 1 3 ...
Страница 110: ......
Страница 115: ...Display Cine Review 6 5 6 Tap Return on the screen or tap Freeze to exit image compare ...
Страница 120: ......
Страница 124: ......
Страница 156: ......
Страница 174: ......
Страница 192: ...12 18 Setup Select Advanced and do as follows Select MAPS and do as follows ...
Страница 202: ...13 2 Probes and Biopsy C5 2s L12 4s L7 3s P4 2s L14 6s C11 3s L14 6Ns V11 3Ws P7 3Ts 7LT4s ...
Страница 203: ...Probes and Biopsy 13 3 7L4s P10 4s L20 5s P7 3s L14 5sp SC6 1s SP5 1s 6CV1s L9 3s C5 1s L11 3VNs C4 1s ...
Страница 222: ...13 22 Probes and Biopsy No Name Description 8 Grooves of the needle guided bracket Matched with the tabs of the probe ...
Страница 226: ...13 26 Probes and Biopsy NGB 034 NGB 035 ...
Страница 250: ......
Страница 272: ......
Страница 276: ...A 4 Wireless LAN Tap Add Manually create a network profile to set ...
Страница 282: ......
Страница 318: ......
Страница 322: ......
Страница 323: ...P N 046 006959 07 1 0 ...