6-6 Display & Cine Review
6.7
Cine Saving
Live capture
Live capture refers to saving the images or cines in image scanning status. After storing, the
system continues with image scanning.
Live capture can be divided into two types: retrospective and prospective.
Retrospective saving saves specified images which were captured before the current
moment. Images stored in the cine memory are saved to the system's hard drive.
Prospective saving saves specified images which are captured later than the current
moment. Images are saved to both the cine memory and the system's hard drive.
The live capture time can be set.
To perform live capture:
Tap [Pro Capture] or [Retro Capture] in LVO real-time mode.
Tap [Save Clip] to pro/retro capture the images (setting path: [Setup] -> [System] ->
[General]->”Live Capture”->[Save Clip])
Frozen image storage
In frozen mode, tap [Save Cine].
6.8
Preset
6.8.1 Setting Cine Length
Select [Setup] -> [System] -> [General] to perform the following settings:
Cine saving storage (for [Save Clip] at the bottom of the operating panel)
Live capture
Type: Retrospective, Prospective. (for [Retro Capture] and [Pro Capture] in LVO mode)
Cine length:
Tip: If the value is out of range, the system can change it to the acceptable effective value.
Содержание TE5
Страница 1: ...TE7 TE5 Diagnostic Ultrasound System Operator s Manual Basic Volume ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ......
Страница 36: ......
Страница 54: ......
Страница 56: ...4 2 Exam Preparation 4 1 1 New Patient Information The Patient Info screen is shown as follows 2 1 3 ...
Страница 110: ......
Страница 115: ...Display Cine Review 6 5 6 Tap Return on the screen or tap Freeze to exit image compare ...
Страница 120: ......
Страница 124: ......
Страница 156: ......
Страница 174: ......
Страница 192: ...12 18 Setup Select Advanced and do as follows Select MAPS and do as follows ...
Страница 202: ...13 2 Probes and Biopsy C5 2s L12 4s L7 3s P4 2s L14 6s C11 3s L14 6Ns V11 3Ws P7 3Ts 7LT4s ...
Страница 203: ...Probes and Biopsy 13 3 7L4s P10 4s L20 5s P7 3s L14 5sp SC6 1s SP5 1s 6CV1s L9 3s C5 1s L11 3VNs C4 1s ...
Страница 222: ...13 22 Probes and Biopsy No Name Description 8 Grooves of the needle guided bracket Matched with the tabs of the probe ...
Страница 226: ...13 26 Probes and Biopsy NGB 034 NGB 035 ...
Страница 250: ......
Страница 272: ......
Страница 276: ...A 4 Wireless LAN Tap Add Manually create a network profile to set ...
Страница 282: ......
Страница 318: ......
Страница 322: ......
Страница 323: ...P N 046 006959 07 1 0 ...