16
KATANA S610M Inverter Specialized for Elevator Manual
Group F07 Input & Output Terminal Setting
F07.00
Function selection of
input terminal X1
0
:
Non functional
1
:
Upward(UP)
2
:
Downward(DN)
3
:
Multi-speed selection1
4
:
Multi-speed selection2
5
:
Multi-speed selection3
6
:
External reset input
7
:
External error input
8
:
Inspection input
9
:
Operation permission of the
inverter
10
:
Emergency operation input
11
:
Operating contactor feedback
input(CSM)
12
:
Braking feedback input (BSM)
13
:
Up forced deceleration speed
input (UPF)
14
:
Down forced deceleration speed
input (DNF)
15: Up leveling input
16: Down leveling input
Others
:
reserved
1
9
×
F07.01
Function selection of
input terminal X2
1
6
×
F07.02
Function selection of
input terminal X3
1
1
×
F07.03
Function selection of
input terminal X4
1
2
×
F07.04
Function selection of
input terminal X5
1
3
×
F07.05
Function selection of
input terminal X6
1
4
×
F07.06
Function selection of
input terminal X7
1
5
×
F07.07
Function selection of
input terminal X8
1
0
×
F07.08
Function selection of
input terminal X9
(Reserved)
1
0
×
F07.09
Function selection of
input terminal X10
(Reserved)
1
0
×