9
KATANA S610M Inverter Specialized for Elevator Manual
After the control panel is replaced, the parameters must be properly set before operation;
otherwise there may be damages to the inverter and other properties.
The exposed cable nose used for main circuit wiring must by wrapped with insulating tape to
avoid electric shocks.
Be sure not to mix the input terminals with the output terminals of main circuit of the inverter,
otherwise there may be risks of damage to the machine, explosion or fire disaster.
Attentions
Please hold the bottom of the product instead of the exterior cover when carrying or installing it,
to avoid dropping down to hurt feet or causing damages to the machine.
Installation shall be made in a place solid enough to bear the weight of the inverter, or the
inverter may drop down and cause injuries and property damages.
It is strictly prohibited to install the inverter nearby a water pipe, or where there may be water
splash, otherwise the machine is in risk of damages.
Do not install the inverter under direct sunlight, otherwise damages may occur.
During installation, never drop the drilling debris into the inverter, otherwise it may cause failure.
Never drop any foreign objects such as screw, gaskets and metal rods into the inverter; otherwise
there is a risk of fire and damages to other properties.
Terminals of the main circuit and the wire end sleeves must be firmly connected; otherwise there
may be damages.
Do not install or operate the inverter if it is damaged or short of spare parts, otherwise there is a
risk of fire or injury.
1.3 Precautions for operation
Please pay attention to the following points when operating the S610M inverter:
1.3.1 Pertaining to the motor and mechanical load
1)
Comparison with power frequency operation
The S610M series are voltage inverter with PWM wave output containing certain harmonic. Therefore,
the temperature rise, noise and vibration of the motor are slightly larger in normal operation compared to
power frequency operation.
2)
Constant-torque low-speed operation
When driving an ordinary motor to run at low speed for a long time, the inverter needs to reduce
output torque due to worse cooling effect of the motor. If constant torque operating at low speed for a long
time is required, a variable-frequency motor is requisite.
3)
Electronic thermal protection value of the motor