![Katana S610M Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/katana/s610m/s610m_user-manual_3606458048.webp)
18
KATANA S610M Inverter Specialized for Elevator Manual
F07.18
Frequency
arrival
(FAR) detected width
0.00
~
100.00
0.01Hz
2.50
○
F07.20
FDT1 level
0.00
~
100.00
0.01Hz
50.00
○
F07.21
FDT1 delay
0.00
~
100.00
0.01Hz
1.00
○
F07.22
FDT2 level
0.00
~
100.00
0.01Hz
25.00
○
F07.23
FDT2 delay
0.00
~
100.00
0.01Hz
1.00
○
F07.24~
F07.37
Reserved
Group F08 Encoder Parameters
F08.00
PG type
0: ABZ incremental
1: SIN/COS
2
:
Endata Absolute Value
-
Heidenhain
ECN1313/ECN413
(reserved)
3
:
UVW incremental (reserved)
Note: 0 is for asynchronous motor
and 1~3 are for synchronous motor
1
1
○
F08.01
PG
pulses
per
revolution
1
~
10000
1
2048
○
F08.02
PG rotating direction
0: A ahead of B
1: B ahead of A
1
0
×
F08.03
Speed
measurement
filtering constant of the
encoder
Units digit: 0~9 high speed filtering
Tens digit: 0~9 low speed filtering
Hundreds digit: 0~9 zero- speed
filtering constant
Thousands
digit:
0
:
speed
measurement method1
1: speed measurement method 2
2:reserved
1
1011H
○
F08.04
PG
thread
break
detection time
0.0
:
no action
0.1
~
10.0
0.1s
2.0
○
F08.05
SIN/COS encoder
zero-offset correction
0: no correction
1:correction
1
0
×
F08.06
SIN/COS encoder
zero-offset of A phase
0~4096
1
2252
*
F08.07
SIN/COS encoder
zero-offset of B phase
0~4096
1
2252
*
F08.08
SIN/COS encoder
zero-offset of C phase
0~4096
1
2252
*
F08.09
SIN/COS encoder
zero-offset of D phase
0~4096
1
2252
*
Group F09 Protection Parameters Setting
F09.00
Relay
output
action
selection when in errors
LED units digit: undervoltage error
action selection
0: no action
1: action (undervoltage regarded
as an error)
1
000
×