121
KATANA S610M Inverter Specialized for Elevator Manual
Error
Code
Error
Description
Possible Causes
Solutions
42
Start running from down
end-station to upward, the
running range is disconnected
when down forced exchange
switch 2 has closed but switch
3 still doesn’t close ( 3 pair of
switches), or down forced
exchange switch 2 has closed
but up forced exchange switch
2 still doesn’t close (have 2
pair of switches).
43
Start running from down
end-station to upward, the
running range is disconnected
when down forced exchange
switch 3 has closed but doesn’t
encounter in up forced
exchange switch 3.
44
Start running from down
end-station to upward, the
running range is disconnected
when has encountered in up
forced exchange switch 3 but
doesn’t encounter in up forced
exchange switch 2.
45
Start running from down
end-station to upward, the
running range is disconnected
when has encountered in up
forced exchange switch 2 but
doesn’t encounter in up forced
exchange switch 1.
5
Start running from down
end-station to upward, the
running range is disconnected
when has encountered in up
forced exchange switch 1 but
doesn’t encounter in up
end-station leveling switch.
6
Start running from down
end-station to upward, the
running range is disconnected
when has encountered in up
end-station leveling switch.
98
Start running from down
end-station to upward, up
forced exchange switch 1 close
while still doesn’t leave down
end-station leveling switch.