KATANA S610M Inverter Specialized for Elevator Manual
Figure 4-6 Example for restoring to the factory setting
4.2 Operation modes of the inverter
4.2.1 Operating mode of the inverter
Operating mode means the way in which the inverter receives the run commands (such as start, stop) and
speed command. S610M serial inverter supports five operating modes, which can be chosen through function
code F00.02:
1. Under operation panel control: use RUN and STOP keys on the operation panel for run commands control,
and F00.03 for setting speed command.
2. Reserved
3. Under the terminal speed control: use the terminals UP (upward) and DN (downward) to control the run
commands and multi-speed terminals MS1~MS3 to set speed commands.
4. CAN communication speed reference/given control: operational command is given by CAN
communication. Speed command is given by CAN communication multi-speed.
5. CAN communication distance control: operational command is given by CAN communication. According
to master PC communication set target floor, operating speed is directly berthed and automatically calculated in
the view of distance principle.
Attentions:
Switching test must be conducted before the command channel is switched, otherwise injuries or
damages to equipment might occur.