24
KATANA S610M Inverter Specialized for Elevator Manual
F13.00
Reserved
F13.01
Reserved
F13.02
Parameters
protection
setting
0: Modification on all parameters
permitted
1: except main digital frequency
reference
(F00.03)
and
this
parameter (F13.02), modification
on other parameters prohibited
2: except this parameter (F13.02),
modification
on
all
other
parameters prohibited
1
1
○
F13.03
Parameter initialization
0: parameter modification status
1: delete error records
2: restore to factory default setting
1
0
×
F13.04
Parameters copy
0: no action
1: upload parameters
2: download parameters
3: download parameters (except
motor parameters)
Note: no upload/download of the
inverter parameters
1
0
×
F13.05
Parameters
display
selection
Binary setting:
0
:
no display
;
1
:
displayed
LED units digit
:
BIT0
:
output frequency (no
display when shutdown)
BIT1
:
the set frequency
(flashing)
BIT2
:
output current (no display
when shutdown)
BIT3
:
output voltage (no
display when shutdown)
LED tens digit
:
BIT0
:
AI1
BIT1
:
AI2
BIT2
:
reserved
BIT3
:
DI (terminal status
setting). When set to 1, the
lower 9 bits display X1
~
X9
,
while higher bits display
output terminals Y1, Y2, and
relay A, B.
LED hundreds digit
:
BIT0
:
output power (no
display when shutdown)
BIT1
:
output torque (no
display when shutdown)
BIT2: feedback speed(m/s)
BIT3: given speed(m/s)
1
1C07H
○