![Katana S610M Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/katana/s610m/s610m_user-manual_3606458050.webp)
20
KATANA S610M Inverter Specialized for Elevator Manual
F09.04
Motor
overload
protection selection
0: no action
1:
general
motor
(low-speed
compensation needed)
2: variable-frequency motor (no
need for low-speed compensation)
1
1
×
F09.05
Selection 1 of special
errors shielding
LED units: Sincos Encoder
CD error shielding selection LED
tens: Sincos Encoder AB low-speed
error shielding selection
LED hundreds: Encoder Z pulse
error shielding selection
LED thousands: Car uncontrollable
error shielding selection
0: Unshielded, warn the error and
stop
1: Shielded
1
0000
×
F09.06
Selection 2 of special
errors shielding
LED units: Basic pole sealing error
shielding selection.
LED tens: CAN communication
error shielding selection
LED handreds: error shielding
selection of magnetic pole tuning
LED thousands: reserved
0: Unshielded, warn the error and
stop
1: Shielded
1
0000
×
F09.07
Error locking selection
0: error locking prohibited
1: error locking permitted
1
0
×
F09.08
Wiring-brake
action
selection of Encoder
0: Warn the error and stop
1: Cut-over SVC then warn the
error after stop
1
0
×
F09.09
Selection
of
special
protection disposition
LED units: derating diagnosis for
flying car distance protection.
0: Prohibit
1: Enable
LED tens: one-key slip enable
0: Prohibit
1: Enable
LED hundreds: poweron handling
mode
of
terminal
operation
command
0: operation terminal is available at
the undervoltage state, need trigger
operation terminal to enable runing
command after bus-voltage normal.
1: operation terminal is available at
the undervoltage state, only need
keep operation terminal as the state
of electric level available, runing
command can be enabled after
bus-voltage normal.
LED thousands: Auto-reset enable
for basic pole sealing error
1
0000
×