For CAN communication speed control mode, set of general function codes are showed as table 7-11 and special
function codes are showed as table 7-12.
Table 7-11 general function codes set of CAN communication speed control
Function Code
Name
Recommend set value
Remarks
F00.01
Control mode
selection
Set according to the
actual situation
F00.04
Rated speed of
elevator
Set according to the
actual situation
F00.07
Maximum output
frequency
Set according to the
actual situation
F01.00
Rated power of the
motor
Set according to the
actual situation
Motor nameplate parameter
F01.01
Rated voltage of the
motor
Set according to the
actual situation
F01.02
Rated current of the
motor
Set according to the
actual situation
F01.03
Rated frequency of
the motor
Set according to the
actual situation
F01.04
Rated speed of the
motor
Set according to the
actual situation
F06.00
zero-speed start P
200
Adjusting according to the actual
operational aspect, normally use
factory settings.
F06.01
zero-speed start I
100
F06.02
ASR1-P
20.0
F06.03
ASR1-I
0.200
F06.04
ASR1 output filter
0
F06.05
ASR2-P
20.0
F06.06
ASR2-I
0.200
F06.07
ASR2 output filter
0
F06.08
ASR1/2 switch
frequency
10%
F06.09
None-zero speed
torque limit value
180%
F06.10
Zero-speed torque
limit value
180%
F06.11
ACR-P(No-start
current loop P)
1000
F06.12
ACR-I(No-start
current loop I)
640
F06.13
ACR-P0(Start
current loop P)
2000
F06.14
ACR-I0(Start
current loop I)
640