KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Setting Range
Factory Default
Value
LED units digit
:
BIT0
:
output frequency (no display when shutdown)
BIT1
:
the set frequency (flashing)
BIT2
:
output current (no display when shutdown)
BIT3
:
output voltage (no display when shutdown)
LED tens digit
:
BIT0
:
AI1
BIT1
:
AI2
BIT2
:
reserved
BIT3
:
DI (terminal status setting). The lower 10 bits display X1
~
X10
,
while higher bits
(thousands digit) display output terminals D1, D2 and relay A, relay B.
LED hundreds digit
:
BIT0
:
output power (no display when shutdown)
BIT1
:
output torque (no display when shutdown)
BIT2: feedback speed (m/s)
BIT3: given speed (flashing)
LED thousands digit
:
BIT0
:
Bus voltage
BIT1
:
Operating speed (R/MIN)
BIT2
:
The set speed (R/MIN) (flashing)
Attentions:
Set frequency is displayed by default when the inverter is shutdown, while output frequency is displayed
by default during operation, if the above are all set to zero.
6.15 CAN Communication Distance Control Parameters 1 (Group F20)
F20.00
Quantity of floors
2~64
2
Set total floors of elevator.