27
KATANA S610M Inverter Specialized for Elevator Manual
forced
deceleration
switch 1
F21.12
Height
of
upward
forced
deceleration
switch 2
00.000~60.000
0.001m
00.000
×
F21.13
Height
of
upward
forced
deceleration
switch 3
00.000~60.000
0.001m
00.000
×
F21.14
Height of downward
forced
deceleration
switch 1
00.000~60.000
0.001m
00.000
×
F21.15
Height of downward
forced
deceleration
switch 2
00.000~60.000
0.001m
00.000
×
F21.16
Height of downward
forced
deceleration
switch 3
00.000~60.000
0.001m
00.000
×
F21.17
Decelerate of upward
forced
deceleration
switch 1
0.020~2.000
0.001m/s2
1.200
*
F21.18
Decelerate of upward
forced
deceleration
switch 2
0.020~2.000
0.001m/s2
1.000
*
F21.19
Decelerate of upward
forced
deceleration
switch 3
0.020~2.000
0.001m/s2
0.900
*
F21.20
Decelerate
of
downward
forced
deceleration switch 1
0.020~2.000
0.001m/s2
1.200
*
F21.21
Decelerate
of
downward
forced
deceleration switch 2
0.020~2.000
0.001m/s2
1.000
*
F21.22
Decelerate
of
downward
forced
deceleration switch 3
0.020~2.000
0.001m/s2
0.900
*
F21.23
Speed limit of upward
forced
deceleration
switch 1
0.00~6.00
0.01m/s
0.00
*
F21.24
Speed limit of upward
forced
deceleration
switch 2
0.00~6.00
0.01m/s
0.00
*
F21.25
Speed limit of upward
forced
deceleration
switch 3
0.00~6.00
0.01m/s
0.00
*
F21.26
Speed
limit
of
downward
forced
deceleration switch 1
0.00~6.00
0.01m/s
0.00
*
F21.27
Speed
limit
of
downward
forced
deceleration switch 2
0.00~6.00
0.01m/s
0.00
*
F21.28
Speed
limit
of
downward
forced
0.00~6.00
0.01m/s
0.00
*