KATANA S610M Inverter Specialized for Elevator Manual
Speed control precision
Magnetic flux vector control without PG
:
±0.5%; Magnetic flux vector
control with PG
:
±0.05%
Frequency resolution Digital setting: 0.01Hz; analog setting: max. frequency * 0.05%
Torque boost
Manual torque boost 0.0
~
30.0%
V/F curve
Four setting modes:one is user-defined V/F curve, and the other three are
reduced torque curves (2.0 power, 1.7 power and 1.2 power)
Automatic current
limiting
Automatic limit on current during operation to avoid tripping caused by
frequent overcurrent.
Operating
function
Operation command
channel
Operation command is given by operation panel, control terminals or
communication.
Frequency reference
channel
Frequency is given by digital.
Digital input terminal 8 road digital multifunctional inputs, X1
~
X8, low level input is available.
Digital output terminal 2 road OC output
Relay output terminal
3 programmable relay outputs, 2 of which are NO (normal open) output,
and 1 of which is NC/NO output.
Operation
panel
LED display
The set frequency, output frequency, output voltage and current etc. can be
displayed.
Parameter copy
Parameters can be copied quickly by using operation panel.
Working
ambient
Usage site
Indoor, without direct sunlight, no dusts, no corrosive or flammable gases,
no greasy mist, no vapors, no water dripping or salt etc.
Altitude
Use by derating when the altitude is above 1000m. The output current shall
be derated by 4‰ of the rated current for every 100m increase.
Environment
temperature
-
10
~+
40
℃
(derating usage under ambient temperature of 40
~
50
℃
)
Humidity
20%
~
90%RH, without water condensation
Vibration
< 5.9 m/s
2
(
0.7g
)
.
Storage temperature
-
40
~+
70
℃
Others
Protective function
Overcurrent protection, overvoltage/undervoltage protection, overheat
protection, overload protection, module protection etc.
Protection grade
IP20
Cooling method
Air cooling, with fan control
Installation method
Wall-mounted
2.5 Installation Dimensions & Weight