KATANA S610M Inverter Specialized for Elevator Manual
Chapter 5 Function Codes in Brief
The function codes of S610M serial inverter special for elevator are using (Group # + Function Code) for
identification, i.e. the function code “FX.YZ” refers to the “YZ” parameter in the group X. For example, “F07.08”
refers to the 8
th
parameter in group 07.
Clarification:
“○” in the colomn of “Modification”means: the parameter value is able to be modified under shutdown and
operation states of the inverter.
“×” in the colomn of “Modification”means: the parameter value is not allowed to be modified under the
operation state of the inverter.
“*” in the colomn of “Modification”means: the parameter value is an actual inspection record which cannot
be modified.
“-” in the colomn of “Modification”means: the parameter value is factory default value, which can only be
set by the manufacturer, not allowed for users to modify.
Function
Code
Name
Setting Range
Minimum
Unit
Factory
Default
Value
Modification
Ruser Set
Group F00 Basic Parameters
F00.00
User’s password
0: no password
Other: password protection
1
0
○
F00.01
Control mode selection
The units: control mode selection
0: without PG vector control
1: with PG vector control
The tens: motor type selection
0: asynchronous
1: synchronous
1
11H
×
F00.02
Operation mode
selection
0: digital reference control through
operation panel
1: analog value reference control
through terminals
(
reserved
)
2: multi-speed reference control
through terminals
3: CAN communication speed
reference control
4: CAN communication distance
control
1
2
×
F00.03
Digital speed given by
operation panel
0
~
F0.04
0.001m/s
1.500m/s
○
F00.04
Elevator rated speed
0.100
~
4.000m/s
0.001m/s
1.500m/s
×
F00.05
Running
direction
setting
0: In the same direction
1: In the opposite direction
1
0
○