background image

 

 

 

 

 

 

 

 

 

 

 
 
 

                         

 

 

DXP D0808 Quick Start 

 

 

 

VIEWSIZE THE WORLD

 

 

 

Support any in any out 

 

Support independent output switching 

 

Support hot backup 

 

Support infrared remote control 

 

Can read and store up to 24/36 user 

scenarios 

 

Automatically recognize the formats 

 

Support EDID management 

Содержание DXP D0808

Страница 1: ...ZE THE WORLD Support any in any out Support independent output switching Support hot backup Support infrared remote control Can read and store up to 24 36 user scenarios Automatically recognize the formats Support EDID management ...

Страница 2: ...How to Switch between Input and Output Channel 7 How to Switch One Input to all Outputs 7 How to Read Device Status 8 How to Set LOGO Display when Power on 8 How to Set the EDID 8 How to Set the Language 9 How to Realize Cascade Setting 9 How to Set the Machine Address 9 How to Realize Signal Auto Take 10 How to Lock the Front Panel 10 How to Realize Hot Backup 10 How to Save the Preset Input and ...

Страница 3: ...b fully meet various strict requirements and high quality occasions Products in this series are widely used in large screen projection display engineering electronic teaching command and control center multimedia meetings room etc Switches in this series are equipped with monochromatic LCD RS 232 communication interface RS422 communication interface optional with outage protect function can read a...

Страница 4: ...925771197 Fax 00865925771202 Email sales rgblink com http www rgblink cn 3 Packing Configuration Note Chinese Standard American Standard or European Standard power cord is option The color of the screw driver is randomly when packing Power Cord 9 pin Serial Cable USB Disk Antistatic Bag Screw Driver Certification ...

Страница 5: ...ion Front Panel Button Instruction 1 8 Selection button for input and output channel and number choice of save or call saving modes LOAD Load button MENU Menu and up arrow button LED indicator Power indicator NEXT Down arrow button Mode indicator TAKE Confirm button Com indicator ALL Distributor selection button IR receiver Receive the infrared signal SAVE Save button LCD Panel Show operation menu...

Страница 6: ...Tel 00865925771197 Fax 00865925771202 Email sales rgblink com http www rgblink cn 5 Back Panel Input Interface 1 DVI Input DVI D port Other Interface 3 RS 232 IN serial communication interface 4 RS 232 OUT serial communication interface 5 Switch 6 Power IEC 3 port Output Interface 2 DVI Output DVI D port ...

Страница 7: ...t and Output Channel How to Switch One Input to all Outputs How to Read Device Status How to Set LOGO Display when Power on How to Set the EDID How to Set the Language How to Realize Cascade Setting How to Set the Machine Address How to Realize Signal Auto Take How to Lock the Front Panel How to Realize Hot Backup How to Save the Preset Input and Output Channel How to Load the Saved Input and Outp...

Страница 8: ...a on the front panel for example choose 5 as the output channel Then push any button on input area on the front panel for example choose 3 as the input Channel After setting push the TAKE button to confirm Note Input channel The signal that will be switched to output channel Output channel The signal that connected to display device The number 1 8 means channel 1 8 How to Switch One Input to all O...

Страница 9: ...reen shows the machine address How to Set LOGO Display when Power on 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose LOGO 3 Push the TAKE button to confirm and enter to LOGO setting push the NEXT button to choose ON or OFF then push the TAKE button to confirm How to Set the EDID 1 Push the MENU button on the...

Страница 10: ...NGLISH then push the TAKE button to confirm How to Realize Cascade Setting 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose CASCADE 3 Push the TAKE button to confirm and enter to the cascade setting Push the NEXT button to choose ON or OFF then push the TAKE button to confirm How to Set the Machine Address 1 ...

Страница 11: ...t Panel 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose LOCK 3 Push the TAKE button to confirm Push the NEXT button to choose ON or OFF then push the TAKE button to confirm Push the MENU button for 3 seconds to unlock panel How to Realize Hot Backup 1 Push the MENU button on the front panel and enter to the ...

Страница 12: ... state or push the SAVE button the light is off and exit the save state Note The buttons 1 8 on output area corresponding to save 1 8 and the buttons 1 8 on output area corresponding to save 9 16 How to Load the Saved Input and Output Channel 1 Push the LOAD button on the front panel the button light is on At the same time some buttons 1 8 in output and input area are on and some flash Button on i...

Страница 13: ... and are non transferable RGBlink warranties are only valid to the original purchase owner Warranty related repairs include parts and labor but do not include faults resulting from user negligence special modification lighting strikes abuse drop crush and or other unusual damages The customer shall pay shipping charges when unit is returned for repair Headquarter S603 604 Weiye Building Torch Hi T...

Отзывы: