15
KATANA S610M Inverter Specialized for Elevator Manual
F06.23
Gain on the drive side
when going down
(reserved)
0.000
~
7.000
0.001
1.000
×
F06.24
Gain on the brake side
when going down
(reserved)
0.000
~
7.000
0.001
1.000
×
F06.25
Digital setting of
pre-torque (reserved)
-100.0%~100.0%
0.1%
10%
×
F06.26
Voltage outer loop KP
0~1000
1
0
×
F06.27
Voltage outer loop TI
coefficient
0.001~1.000
0.001
0.050
×
F06.28
Magnetic flux set
percentage of geared
motor
50%~130%
1%
100%
×
F06.29
PerUnit of weak
magnetic Max. current
0~4096
1
410
×
F06.30
Margin of Max. voltage
0~100.0
0.1
3.0
×
F06.31
Control optimization
mode selection
LED unit: SVC mode selection of
asynchronous motor
LED tens: SVC mode selection of
synchronous motor
LED hundreds: V/F mode selection
LED thousands: slip compensation
optimization enable mode
0: mode 0
1: mode 1
1
1111H
×
F06.32
FVC coefficient of
asynchronous motor
0~100
1
10
×
F06.33
SVC filter time of
asynchronous motor
0~200
1
15
×
F06.34
SVC filter time of
synchronous motor
10~1000
1
100
×
F06.35
0 current given at SVC
mode of synchronous
motor
0~100
1
30
×
F06.36
Mode 1 switch
frequency
0~100%
1%
25%
×
F06.37
Mode 1 low-frequency
current given
0~2000
1
1200
×
F06.38
Mode 1 adjust
coefficient
0~100
1
12
×
F06.39
Current filtering
coefficient
Units: 0~3 D axial current filtering
Tens: 0~3 Q axial current filtering
1
00H
×
F06.40
Mode 1 low-frequency
current given (UPS
operation)
0~2000 (relative motor rated
current)
1000 corresponds to motor rated
current
1
800
×
0~2000