30
KATANA S610M Inverter Specialized for Elevator Manual
seconds delay to reset.
4.
Axxx will be displayed on the
operation panel when failure
warning
starts
(e.g.
when
contactor error occurs, E018
will be displayed on the
operation
panel
if
error
protection acts, while A018
will be displayed if operation
continues with warning.
Other: reserved
F90.01
Sub-code
of
error
recording 1
0
~
65535
1
0
*
F90.02
Bus voltage when error
occur
0
~
999
1V
0V
*
F90.03
Output voltage when
error occur
0
~
480V
1V
0V
*
F90.04
Actual current when
error occurs
0.0
~
999.9
0.1A
0.0
*
F90.05
Set
frequency
when
error occurs
0.00Hz~100.00Hz
0.01Hz
0.00Hz
*
F90.06
Operating
frequency
when error occurs
0.00
~
100.00
0.01Hz
0.00
*
F90.07
Operating status of the
inverter
when
error
occurs
0
~
FFFFH
1
0000
*
F90.08
Error record 2
0
~
99
1
0
*
F90.09
Sub-code
of
error
record 2
0
~
65535
1
0
*
F90.10
Error record 3
0
~
99
1
0
*
F90.11
Sub-code
of
error
record 3
0
~
65535
1
0
*
F90.12
Error record 4
0
~
99
1
0
*
F90.13
Sub-code
of
error
record 4
0
~
65535
1
0
*
F90.14
Error record 5
0
~
99
1
0
*
F90.15
Sub-code
of
error
record 5
0
~
65535
1
0
*
Group F91 Inverter Parameters
F91.00
Serial number
0
~
FFFF
1
610
*
F91.01
Software version #
0.00~99.99
1
2.01.06
*
F91.02
Customized version #
0
~
9999
1
1.00
*
F91.03
Temporary version #
00.000~64.999
1
Factory
setting
*
F91.04
Rated capacity
Output power 0
~
999.9 KVA
(
Auto decided and set by the
model
)
0.1kVA
Factory
setting
*