Function Code
Name
Recommend set value
Remarks
of input terminal
X2
F07.02
Function selection
of input terminal
X3
12
Brake feedback input
F07.11
Input terminal
activeness setting
Set according to the
actual situation
Input terminal Normal Open/Normal
Close selection
F07.14
Output function of
relay 1
12
Operation contactor control output
F07.15
Output function of
relay 2
11
Brake control output
F07.16
Output function of
relay 3
7
Inverter error
F07.18
Output terminal
activeness setting
Set according to the
actual situation
Output terminal Normal Open/Normal
Close selection
F12.05
Baud rate of CAN
communication
Set according to the
actual situation
F12.08
Detection time of
Can communication
overtime (under
CAN mode)
2.0s
Adjust according to the actual
situation
F20.00
Quantity of floors
Set according to the
actual situation
Adjust according to the actual
situation
F20.02
Run speed
Set according to the
actual situation
Adjust according to the actual
situation
F20.07
Average
acceleration and
deceleration
Set according to the
actual situation
Adjust according to the actual
situation
F20.08
Inspection Speed
0.30m/s
F20.09
Inspection
acceleration time
1.0s
F20.10
Inspection
deceleration time
0.3s
F20.11
Operation speed of
non fast running
terminal station.
0.10m/s
F20.12
leveling speed of
non
terminal
station.
0.20m/s
F20.13
Speed of hoistway
self-tuning
0.30m/s
F20.14
Security diagnosis
of elevator
0
If F20.07 and F20.17 are changed, the
elevator safety diagnosis must be
re-conducted. Set F20.14=1 to start
safe diagnosis. If the diagnosis is