56
KATANA S610M Inverter Specialized for Elevator Manual
LED digit refers to the units digit, tens digit, and hundreds digit of LED displayed on the operation panel.
Attentions:
The factory default settings for all the terminals are positive logic.
F07.12
Open collector output Y1
0
~
20
0
F07.13
Open collector output Y2
0
~
20
0
F07.14
Relay 1 output
0
~
20
0
F07.15
Relay 2 output
0
~
20
0
F07.16
Relay 3 output
0
~
20
0
Open collector output Y1, Y2 and relay 1
~
3 can be defined for multifunction. Please refer to Table 2-5 for output functions:
Table 6-5 Output terminal functions list
Value
Corresponding function
Value
Corresponding function
0
Non functional
1
Inverter running signal
(RUN)
2
Frequency arrival signal
(FAR)
3
Frequency level detection
signal (FDT1)
4
Frequency level detection
signal (FDT2)
5
Inverter ready to operate
(RDY)
6
Stopping the inverter
c used by under-voltage
(LU)
7
Inverter failure
8
Up signal output
9
Down signal output
10
Inverter operating at zero
speed
11
Braking control output
12
Operating contactor control
output
13
Signal of Motor enables to
open the brake.
14
Direction signal with
light-load
15
Pre-open door output
16
Braking power output
17
Output of basic pole block
error (E030)
18
Inverter is ready (no
relationship with enable
signal of Inverter)
1: Inverter running signal (RUN)
The terminal outputs signal indicating that the inverter is in operation.
2: Frequency arrival signal (FAR)
Please refer to F07.19 for function explanation.
3: Frequency level detection signal (FDT1)
Please refer to F07.20
~
F07.21 for function explanation.
4: Frequency detection signal (FDT2)
Please refer to F07.22
~
F07.23 for function explanation.