47
KATANA S610M Inverter Specialized for Elevator Manual
Function
Code
Parameter Name
Setting Range
Factory Default
Value
F05.06
Rapid deceleration near the end
0.020~9.999 m/s
3
0.350
Parameters F05.01
~
F05.06 are to set word
S
of the curve. Word
S
can prevent vibration when the
elevator starts/stops, thus to improve comfort degree.
Setting of word
S
includes acceleration, rapid acceleration (acceleration plus speed) and
deceleration, rapid deceleration (
variation rate of deceleration
speed), as shown in Figure 2-9:
Figure 6-9 S curve parameters sketch
F05.07
Acceleration under inspection operation
0.020~9.999 m/s
2
1.000
This parameter defines elevator’s acceleration in Inspection&Maintenance operation mode (Speed mode
available).
F05.08
Deceleration under inspection operation
0.020~9.999 m/s
2
1.000
This parameter defines elevator’s deceleration in Inspection&Maintenance operation mode (Speed mode
available).
F05.09
Acceleration under emergency
operation
0.020~9.999 m/s
2
1.000
This parameter defines elevator’s acceleration speed in emergency operation mode.
F05.10
Deceleration under emergency
operation
0.020~9.999 m/s
2
1.000
This parameter defines elevator’s deceleration speed in emergency operation mode.
F05.11
Acceleration under auto tuning
operation (Reserved)
0.020~9.999 m/s
2
0.150
This parameter defines motor’s acceleration speed during parameter auto tuning.
F05.12
Deceleration under auto tuning
operation (Reserved)
0.020~9.999 m/s
2
0.150
This parameter defines motor’s deceleration speed during parameter auto tuning.
F05.13
Deceleration under abnormal condition
0.020~9.999 m/s
2
1.000
This parameter defines deceleration speed when forced deceleration is valid.
F05.14
Deceleration when stops
0.020~9.999 m/s
2
0.550
This parameter defines deceleration speed from non-zero to zero.
F05.03
F05.05
v
F05.02
F05.01
F05.04
F05.06
F05.00
t