12
KATANA S610M Inverter Specialized for Elevator Manual
control
F02.14
Braking frequency of
none close loop control
0.00~10.00HZ
0.01HZ
0.00
×
F02.15
Open brake frequency
of none close loop
control (UPS operation)
0.00~10.00HZ
0.01HZ
1.50
×
0~1000
F02.16
Braking frequency of
none close loop control
(UPS operation)
0.00~10.00HZ
0.01HZ
1.50
×
0~1000
Group F03 Speed Parameters
F03.00
Multi-section speed 0
0
~
F0.04
0.001M/S
0
○
F03.01
Multi-section speed 1
0
~
F0.04
0.001M/S
0
○
F03.02
Multi-section speed 2
0
~
F0.04
0.001M/S
0
○
F03.03
Multi-section speed 3
0
~
F0.04
0.001M/S
0
○
F03.04
Multi-section speed 4
0
~
F0.04
0.001M/S
0
○
F03.05
Multi-section speed 5
0
~
F0.04
0.001M/S
0
○
F03.06
Multi-section speed 6
0
~
F0.04
0.001M/S
0
○
F03.07
Multi-section speed 7
0
~
F0.04
0.001M/S
0
○
F03.08
Inspection speed
0.000~0.630 m/s
0.001
M/S
0.2M/S
×
F03.09
Emergency speed
0.020~0.150 m/s
0.001
M/S
0.1M/S
×
F03.10
Speed detection of up
forced deceleration
0
~
100.0%
(
F00.04
)
0.1%
97.0%
×
F03.11
Speed detection of
down forced
deceleration
0
~
100.0%
(
F00.04
)
0.1%
97.0%
×
F03.12
Overspeed setting
80.0%
~
130.0%
(
F00.04
)
0.1%
120.0%
×
F03.13
Detection time of
overspeed
0: Prohibited
0.01~2.00s
:
Inspection time
0.01S
0.30S
×
F03.14
Speed deviation range
0: Prohibited
10.0%~50.0%(F00.04)
:
speed
deviation range
0.1%
20.0%
×
F03.15
Detection time of speed
deviation
0: Prohibited
0.1~5.0 s
:
Inspection time
0.1S
1.0
×
F03.16
Crawling speed
0.020~0.500 m/s
0.001
M/S
0.050 M/S
×
F03.17
Selection of
multi-speed detection
0
~
7
0
:
invalid
1
~
7: the corresponding
multi-speed is 1
~
7
(
F03.01
~
F03.07
)
when none of the digital
input terminals is set as inspection
operation terminal INS.
1
0
×