background image

Shenzhen danfly technology co.,ltd

0755-29524002

13510025117

1

DFL-VF series inverter user manual

(

V308

)

This manual provides users

with installation, parameter settings, Fault diagnosis, and

Routine maintenance. To ensure proper operation ,please read and keep it carefully

Warning:

1

Please power off before wiring!

2

Please don

t insert objects into main circuit board or touch it, since the electronic

components are particularly sensitive to static electricity

3

After cutting off AC power , some electronic parts may remain a residual high-voltage, touch

the internal circuit or components is prohibited especially when the indicator is light on.

4

Output terminals connecting to power is absolutely prohibited!

5

Make sure the inverter terminals is properly grounded

6

If you will not use the inverter for a long time, please cut off power!

This manual is specially for DFL-VF Series, software version is :V308.9 . Since our

products and specifications are constantly updated , this manual is used for software version
V308.0-V308.9. The real function of your order might be different with this file .

Software version illustration:
220V series :

V308.0-V308.9

V308.1 suitable for special inverter matches with single phrase motor
V308.2 suitable for constant pressure water supplying inverter
V308.3 suitable for wire cutting inverter
V308.4 suitable for electric spindle inverter
V308.5 suitable for knitting machine dedicated inverter
V308.6 suitable for terminal machine inverter
V308.7 suitable for environmental protection air conditioner inverter
V308.9 suitable for 220V universal inverter

380V series : V408.0-V408.9
V408.9 suitable for 380V universal inverter

Please contact us when you have any questions about our products
Telephone : 86-755-29524002
Fax

: 86-755-29524003

Summary of Contents for DFL-VF series

Page 1: ...se the inverter for a long time please cut off power This manual is specially for DFL VF Series software version is V308 9 Since our products and specifications are constantly updated this manual is used for software version V308 0 V308 9 The real function of your order might be different with this file Software version illustration 220V series V308 0 V308 9 V308 1 suitable for special inverter ma...

Page 2: ...age happened during transportation 2 Open the package and find out the user manual 3 Check the nameplate information on side of the inverter be sure you get the right product or spare parts For any problem you may have please contact your supplier STORAGE Inverter should be packed and stored in ventilate and dry place Keep it away from corrosive gas liquid and stained conditions The relative Humid...

Page 3: ...enzhen danfly technology co ltd 0755 29524002 13510025117 3 1 2 Description of nameplate Designation for model name information Chapter 2 Installation and wiring 2 1 DFL200S Series Installation Dimension ...

Page 4: ...Shenzhen danfly technology co ltd 0755 29524002 13510025117 4 2 2 DFL3000A 4000A Series Installation Dimension ...

Page 5: ...Shenzhen danfly technology co ltd 0755 29524002 13510025117 5 2 3 DFL200S DFL3000A 220V basic wiring diagram ...

Page 6: ...AC 250V2A以下 DC 30V2A以下 A B RS 485 Serial interface shows main circuit shows control circuit X1 X2 X3 X4 X5 X6 COM 10V FV FI ACM Multi function input 4 Grounding DFL VF Series Inverter Basic Wiring Diagram CM NC NO COM X1 X2 X3 X4 X5 X6 DCM FO ACM FI FV 10V A B DFL HJ01 Control terminal block descriptions Multi function indication output Multi function input Analog voltage input RS485 Multi functio...

Page 7: ...Shenzhen danfly technology co ltd 0755 29524002 13510025117 7 2 5 Control circuit wiring The Control circuit wiring should be separated from the main circuit wiring Do ...

Page 8: ...ld up 16 speeds 0000 refers first speed 0001 refers to second speed 0010 refers to third speed 0011 refers to fourth speed 1111 is the 16th speed X2 COM The second input terminal X3 COM The third input terminal X4 COM The fourth input terminal FWD COM Forward rotation Stop Run Stop Stop forward rotate REV COM Reversion Stop Run pause Stop reverse DCM Digital signal FO DCM Analog Cymometer galvanom...

Page 9: ... Speed instruction power A Communication terminal A RS485 B Communication terminal B The control signal wire is shielded and stranded Wire for RS 485 communication should be the twisted pair 2 4 Safety Considerations 1 Please use right wires according to relative laws When the distance between inverter and motor is over than 25meters should raise wiring standard Between the three phase AC input po...

Page 10: ...ound don t make a ground loops 7 Confirm the voltage and maximum current 8 The power indicator on the side of inverter shows the voltage inside the inverter 9 When the power indicator is lighting do not connect or disassemble wires 10 The DFL VF series is not equipped with the brake resistor In the occasion of frequently starting or stopping inverters please install brake resistor or unit 11 Pleas...

Page 11: ...description refers to different parts LED indication Red lamp lights during RUN STOP JOG FWD or REV operation LED display Indicates frequency motor current and alarm contents Forward Reverse key Selects FWD or REV operation Jog key While pressing this key jog speed is available Run key Starts inverter drive peration Program Reset key Selects normal mode program mode Displays the motor drive status...

Page 12: ...content Then Press this button again will save the changed parameters to the internal memory Select forward or reverse operation Press this button the motor will decelerate to 0HZ and change direction but motor will not restart automatically after the shutdown An external terminal can control motor forwarding or reversing when modify Pr 001 to d0001 or d0002 Press this button the motor will run at...

Page 13: ...pecified parameter code The present parameter Value will be displayed by pressing the key Display present parameters Press the key to store the modified parameters The parameter is accepted and stored automatically at internal memory when the end as left picture remains approximately 1 second on the display 3 3 LED indicators RUN light up means working STOP red light means stop working JOG red lig...

Page 14: ...danfly technology co ltd 0755 29524002 13510025117 14 四 Digital Keypad Operating Modes Programming steps MODE Increase the frequency Decrease the frequency MODE NOTES Display changes every time or key is pressed ...

Page 15: ... the parameter 按 Press DATA key to store the data 按 键 Indication after power on P r e 按 键 Output frequency Frequency command Output current 按 Press DATA key to display 按 Press up down key to set 按 键 不存储资料回到正常操作模式 按 键 Press PRGM key return to the normal operation mode Data entered will not be stored 按 键 Press PRGM key return to the normal operation mode ...

Page 16: ... is determined by digital operator d0000 d0001 Run command is determined by external terminals STOP key is valid d0002 Run command is determined by external terminal decision STOP key is invalid d0003 Run command is determined by the RS 485 serial communication interface STOP key is valid d0004 Run command is determined by RS 485 serial communication interface STOP key is invalid Pr 002 selection ...

Page 17: ...it reversal setting Notes Inverter will stop REV function without reminding when prohibit reversal is setup d0000 Allow Reversal d0000 d0001 Prohibit reversal Note REV and FWD are relative concept Please carefully check the motor direction in the occasion of reversing is not allowed Pr 017 setting for over voltage stall prevention Over voltage stall prevention setting d0000 Over voltage stall prev...

Page 18: ...025 Pr 025 Setting for restarting time after momentary power loss d000 3 d005 0 s d000 2 Pr 026 Setting for the Max tracking time when power on d000 3 d005 0 s d000 5 Pr 027 Selection of the max current for speed tracking d0030 d0200 d0150 Pr 028 Selection of the max input analogy frequency d000 0 d120 0 Hz when Pr 000 1 d050 0 Pr 029 Selection of the min input analogy frequency d000 0 d120 0 Hz w...

Page 19: ... d0012 Counter function when pulse frequency is lower than 500HZ d0013 Counter reset function clear present data d0014 Receive external sudden stop signal can reset automatic d0015 0 start function timer multi function output action d0016 X4 is the input terminal for A mode always close d0017 AUTO RUN PLC d0018 PAUSE for PLC d0019 PID is valid connect junction start PID d0020 No function Isolate t...

Page 20: ...00 V it s whenPr 000 1 d00 00 Pr 043 Set the rated speed for motor d0000 d3000 d1500 Pr 044 Set the rated current for motor d0030 d0120 d0100 Pr 045 Set the no load current for motor d0000 d0099 d0040 Pr 046 Torque compensation setting d0000 d0010 d0000 Pr 047 Set the torque gain at accelerating whenPr 011 0 d0010 d0200 d0100 Pr 048 Set the torque gain decelerating whenPr 011 0 d0010 d0200 d0100 P...

Page 21: ...tinues after over torque detection Pr 053 Over torque detection d0030 d0200 d0150 Pr 054 Over torque detection time d000 1 d010 0 s d000 1 Pr 055 Energy brake setting d0001 d9999 d0000 Pr 056 Count attained setting Count attained setting d0001 d9999 d0000 Pr 057 Function display Output physical setting d0000 Displays the actual operating freq H d0001 Displays the actual operating running speed H d...

Page 22: ...or fuse failure GFF d0014 16 Reserved for manufacture diagnosis d0017 External base block bb d0018 Overload 2 oL2 d0019 20 Reserved for manufacture diagnosis Pr 066 Second fault record d0000 Pr 067 Third fault record d0000 Pr 068 Parameter lock restore setting d0000 parameters can be written and read need 5 to 10 minutes to reset d0000 d0001 parameters are read only d0002 d0009 Reserved d0010 Rest...

Page 23: ... Pr 092 Deceleration time 10 d00 01 d99 99 s d00 02 Pr 093 Acceleration time 11 d00 01 d99 99 s d00 02 Pr 094 Deceleration time 11 d00 01 d99 99 s d00 02 Pr 095 Acceleration time 12 d00 01 d99 99 s d00 02 Pr 096 Deceleration time 12 d00 01 d99 99 s d00 02 Pr 097 Acceleration time 13 d00 01 d99 99 s d00 02 Pr 098 Deceleration time 13 d00 01 d99 99 s d00 02 Pr 099 Acceleration time 14 d00 01 d99 99 ...

Page 24: ... value of PID MPa d00 00 d10 00mpa d00 4 Pr 132 Proportional constant d0000 d0999 d0015 Pr 133 Integration time d0000 d0999 d0999 Pr 134 Differential time d0000 d0100 d0000 Pr 135 Source of PID target value d0000 by Pr200 d0001 by external analog 0 10V d0000 Pr 136 PID upper limit d0000 d0100 d0100 Pr 137 PID lower limit d0000 d0100 d0000 Pr 138 Pressure level on shutdown d0000 d0100 d0095 Pr 139 ...

Page 25: ...00 0 Pr 156 Timer 2 d000 0 d999 9 d000 0 Pr 157 Timer 3 d000 0 d999 9 d000 0 Pr 158 Timer 4 d000 0 d999 9 d000 0 Pr 159 Timer 5 d000 0 d999 9 d000 0 Pr 160 Timer 6 d000 0 d999 9 d000 0 Pr 161 Timer 7 d000 0 d999 9 d000 0 Pr 162 Timer 8 d000 0 d999 9 d000 0 Pr 163 Timer 9 d000 0 d999 9 d000 0 Pr 164 Timer 10 d000 0 d999 9 d000 0 七 Troubleshooting and Fault Information Fault code Error and solution ...

Page 26: ...achine is overload please change bigger power inverter Er 10 Communication code error Er 11 Communication data error Er 12 Communication timeout Er 13 Communication calibration error No display power indicator flash 1 check input power ensure the voltage is 150 to 250V AC otherwise need to repair 2 internal power supply detection need to repair No display power indicator dark check input power ens...

Page 27: ... and arbitrary S curve Output voltage at rated frequency function of motion Give operation command frequency setting input signal output signal Panel given external terminals give 485 communication given Panel given analogy voltage given analogy current input given external acceleration and deceleration given 485 communication given FWD REV command Multistep speed control operating command Error i...

Page 28: ...Shenzhen danfly technology co ltd 0755 29524002 13510025117 28 ...

Reviews: