28
KATANA S610M Inverter Specialized for Elevator Manual
deceleration switch 3
F21.29~
F21.91
Height of floors 1…63
00.000~60.000
0.001m
00.000
×
Group F22 Upward Running Leveling Distance Compensation
F22.00~
F22.63
Leveling
distance
compensation
of
upward running floor
1… floor 64
-200
~
200
1mm
0
×
Group F23 Reserved Downward Running Leveling Distance Compensation
F23.00~
F23.63
Leveling
distance
compensation
of
downward
running
floor 1… floor 64
-200
~
200
1mm
0
×
Group F90 Error Records
F90.00
Error record 1
Errors of the inverter:
0
:
no abnormal records
1
:
over current when the inverter
accelerates (E001)
2
:
over current when the inverter
decelerates (E002)
3
:
over current when the inverter
operates at constant speed (E003)
4
:
over voltage when the inverter
accelerates (E004)
5
:
over voltage when the inverter
decelerates (E005)
6
:
over voltage when the inverter
operates at constant speed (E006)
7
:
Abnormal voltage sharing of bus
capacitor (E007) (Reserved)
8
:
Input phase loss (E008)
9
:
Output phase loss (E009)
10
:
Quick overcurrent protection
(E010)
11
:
Radiator 1 overheat (E011)
12
:
Radiator 2 overheat (E012)
13
:
Inverter overload (E013)
14
:
Motor overload (E014)
15
:
External error (E015)
16
:
EEPROM reading & writing
error (E016)
17
:
Communication abnormal of
serial port (E017)
18
:
Abnormal contactor (E018)
19
:
Abnormal circuit by current
detection
(E019
)
Hall
or
amplifying circuit
20: CAN communication abnormal
1
0
*