![Katana S610M Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/katana/s610m/s610m_user-manual_3606458126.webp)
96
KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Recommend set value
Remarks
F06.12
ACR-I(No-start
current loop I)
640
F06.13
ACR-P0(Start
current loop P)
2000
F06.14
ACR-I0(Start
current loop I)
640
F08.00
PG type
Set according to actual
situation
F08.01
PG the number of
pulses per
revolution
Set according to actual
situation
F08.02
PG direction of
rotation
Set according to
actual situation
Table 7-3 Terminal multi-speed operation’s special function code setting table
Function code
Name
Recommend set value
Remarks
F00.02
Operating mode
selection
2
Terminal multi-speed operation mode
F02.02
Maintaining time of
start zero-speed
1.00s
Adjust based on comfort level when
elevator starts
F03.00
Multi-speed 0
0
Decide based on design
F03.01
Multi-speed 1
Re-leveling speed
F03.02
Multi-speed 2
Creeping speed
F03.03
Multi-speed 3
Emergency speed
F03.04
Multi-speed 4
Inspection speed
F03.05
Multi-speed 5
Normal low speed
(speed of single
level)
F03.06
Multi-speed 6
Normal medium
speed (speed of
double level)
F03.07
Multi-speed 7
Normal high speed
(speed of multi-level)
F03.17
Multi-speed selection
4
Multi-speed ins&maintenance
operation
F05.00
Rapid deceleration
when stops
0.35 m/s
3
Adjust according to practical
operation effect
F05.01
Acceleration speed
0.55 m/s
2
F05.02
Rapid acceleration at
the beginning
0.35 m/s
3
F05.03
Rapid acceleration
0.6 m/s
3