13
KATANA S610M Inverter Specialized for Elevator Manual
Note: this function is invalid when
any digital input terminal is set as
inspection operation terminal INS.
Group F04 Analog input curve(reserved)
Group F05 Acceleration and Deceleration Parameters
F05.00
Rapid deceleration
when stops
0.020~9.999 m/s3
0.001
m/s3
0.35 m/s3
×
F05.01
Acceleration speed
0.020~9.999 m/s2
0.001
m/s2
0.55 m/s2
×
F05.02
Rapid acceleration
when starts
0.020~9.999 m/s3
0.001
m/s3
0.35 m/s3
×
F05.03
Rapid acceleration near
the end
0.020~9.999 m/s3
0.001
m/s3
0.6 m/s3
×
F05.04
Deceleration
0.020~9.999 m/s2
0.001
m/s2
0.55 m/s2
×
F05.05
Rapid deceleration at
the beginning
0.020~9.999 m/s3
0.001
m/s3
0.6 m/s3
×
F05.06
Rapid deceleration near
the end
0.020~9.999 m/s3
0.001
m/s3
0.35 m/s3
×
F05.07
Acceleration under
inspection operation
0.020~9.999 m/s2
0.001
m/s2
1.0 m/s2
×
F05.08
Deceleration under
inspection operation
0.020~9.999 m/s2
0.001
m/s2
1.0 m/s2
×
F05.09
Acceleration under
emergency operation
0.020~9.999 m/s2
0.001
m/s2
1.0 m/s2
×
F05.10
Deceleration under
emergency operation
0.020~9.999 m/s2
0.001
m/s2
1.0 m/s2
×
F05.11
Acceleration under auto
tuning operation
0.020~9.999 m/s2
0.001
m/s2
0.15 m/s2
×
F05.12
Deceleration under auto
tuning operation
0.020~9.999 m/s2
0.001
m/s2
0.15 m/s2
×
F05.13
Deceleration under
abnormal condition
0.020~9.999 m/s2
0.001
m/s2
1.0 m/s2
×
F05.14
Deceleration when
stops
0.020~9.999 m/s
2
0.001
M/S
2
0.55 M/S
2
×
Group F06 Control Performance Parameters
F06.00
Zero-speed starting P
(F02.01:working during
the maintaining time of
zero-speed starting and
only valid under
closed-loop control)
1~2000
1
200
○
F06.01
Zero-speed starting I
(F02.01:working during
the maintaining time of
zero-speed starting and
only valid under
closed-loop control)
0~9999
1
100
○