Power:

120 V AC/13.8V AC 1.25A, UL listed adapter provided or

24-48V DC, 100mA

Dimensions:

211mm x 160mm x 46mm (8.3” x 6.5” x 1.8”)

Shipping Weight:

1.2 kg (2.6 lbs)

Environmental:

0°C to 32°C (32°F to 90°F) with 5% to 95%

non-condensing humidity

Connections: 

(1) RJ21X, (1) RJ11

Power Failure Bypass System

P

P

r

r

a

a

c

c

t

t

i

i

c

c

e

e

T

T

E

E

L

L

E

E

C

C

O

O

M

M

S

S

O

O

L

L

U

U

T

T

I

I

O

O

N

N

S

S

F

F

O

O

R

R

T

T

H

H

E

E

2

2

1

1

S

S

T

T

C

C

E

E

N

N

T

T

U

U

R

R

Y

Y

TECHNICAL

TECHNICAL

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

•  Transfers six C.O. trunks directly to the

designated analog station phones

•  Stackable to increase capacity

•  Allows user to receive calls, as well as make

calls during power or system failure

•  Compatible with loop start lines or 48V ground

start lines

•  Automatic ground start converter eliminates

“ground start buttons”

•  Power restoration will not interrupt calls in

progress

•  Operates on power failure or normally open -

normally closed alarm contacts

The 

PF-6A

power failure bypass system makes it

possible to receive calls during phone system and
power outages. The 

PF-6A

bypass unit connects

6 pre-assigned single line station phones directly
to user-assigned C.O. trunks. A built-in ground
start converter permits outbound calls from stan-
dard phones.

When the system is restored, calls in progress are
not lost. The 

PF-6A

bypass unit will reconnect

phones to their station circuits after they become
idle.

The 

PF-6A

can be configured to operate when power is lost or from an opening/closing

of an alarm contact or manual closure.

Alternatively, the 

PF-6A

can be used to convert six incoming ground start lines to loop

start lines.  This accommodates installation of telephony equipment requiring loop start
lines (example: key systems, call sequencers, answering machines, voice mail, etc.)

w

w

w

w

w

w

.

.

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

i

i

n

n

f

f

o

o

@

@

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

•  Prevents busy signals or unanswered calls

during power and system failures

•  Converts ground start lines to standard loop

start lines

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

M

M

a

a

d

d

e

e

i

i

n

n

t

t

h

h

e

e

U

U

.

.

S

S

.

.

A

A

.

.

Отзывы: