P03 group Vector control
Function
code
Name
Description
Default Modify
P03.00
ASR proportional gain
1
0
–200.0
20.0
○
P03.01
ASR integral time 1 0.000
–10.000s
0.200s
○
P03.02
Switching low point
frequency
0.00Hz
–P03.05
5.00Hz
○
P03.03
ASR proportional gain
2
0
–200.0
20.0
○
P03.04
ASR integral time 2 0.000
–10.000s
0.200s
○
P03.05
Switching high point
frequency
P03.02
–P00.03 (max. output frequency)
10.00Hz
○
P03.06
ASR output filter
0
–8 (corresponds to 0–2^8/10ms)
0
○
P03.07
Vector control
electromotion slip
compensation
coefficient
50%
–200%
100%
○
P03.08
Vector control power
generation slip
compensation
coefficient
50%
–200%
100%
○
P03.09
ACR proportional
coefficient P
0
–65535
The default value of P03.09 and P03.10 is
different within differing power ranges, and
the default value will be configured as below
after autotuning and setting power range via
the touch screen.
P03.09 value
(reference)
P03.10 value
(reference)
Motor power
2000
1000
7.5
–22kW
2500
1500
30
–37kW
3000
1500
45
–90kW
3500
2000
110
–132kW
4000
2000
160
–315kW
Depend
on
model
○
P03.10
ACR integral
coefficient I
Depend
on
model
○
P03.20
Keypad setting of the
upper limit of
electromotive torque
0.0
–300.0% (rated motor current)
180.0%
○