Goodrive300-01A series VFD for air compressor
Function code description
-65-
Function
code
Name
Description
Default Modify
P17.22
PT2 input voltage
Display analog input voltage value of PT2
channel.
Under
air-compressor
mode,
connect
to
PT100
thermal
resistor
temperature sensor, different temperature
generates corresponding resistor value, and
different resistor value corresponds to
corresponding input voltage, therefore, input
voltage
value
can
correspond
to
corresponding detection temperature. Input
voltage
P18.32
–P18.33
correspond
to
-20°Cto +150°C.
Setting range: 0.00
–10.00V
0.00V
●
P17.23
PID reference value
Display the set value of discharge pressure
signal. 100% corresponds to the upper limit
value of discharge pressure sensor (P18.04)
(if P18.37=1, 100% corresponds to P18.38).
Setting range: -100.0
–100.0%
0.0%
●
P17.24
PID feedback value
Display the detection value of discharge
pressure signal.
Setting range: -100.0
–100.0%
0.0%
●
P17.25
Motor power factor
-1.00
–1.00
0.0
●
P17.26
Current running time 0
–65535m
0m
●
P17.28 ASR controller output -300.0%
–300.0% (rated motor current)
0.0%
●
P17.29
Magnetic pole angle of
SM
0.0
–360.0
0.0
●
P17.30
Phase compensation
quantity of SM
-180.0
–180.0
0.0
●
P17.31
High-frequency
superposition current
of SM
0.0%
–200.0%
0.0
●
P17.32
Flux linkage
0.0%
–200.0%
0.0
●
P17.33
Exciting current
reference
-3000.0
–3000.0A
0.0
●
P17.34
Torque current
reference
-3000.0
–3000.0A
0.0
●
P17.35
AC incoming current 0.0
–5000.0A
0.0
●
P17.36
Output torque
-3000.0Nm
–3000.0Nm
0.0Nm
●