Goodrive300-01A series VFD for air compressor
External optional accessories
-116-
B.1.4.6 User parameter interface
1. Enter the user parameter interface through the main menu.
03.17 16:02:35
Home
Set pressure xxx.xx Mpa
Return
Edit
User param
Unloading pressure xxx.xx Mpa
Loading pressure xxx.xx Mpa
Setting Temp xxxxxx
Fan Starting Temp xxxxxx
Fan Stopping Temp xxxxxx
03.17 16:02:35
Home
Load/Unload Mode Automatic
Return
Edit
User param
Stop Delay xxxxxx s
No-load Delay xxxxxx s
Restart Delay xxxxxx s
Sleep Function Enable
Loading Delay xxxxxx s
03.17 16:02:35
Home
Timing switch setting
Return
Edit
User param
Sleep Function Enable
Load/Unload Mode Automatic
Power consumption xxxx.x kW.h
Accumlated Run Time xxxxxx h
Restart Delay xxxxxx s
Figure B-12 User parameter interface
User parameter
Initial value
Function
Set temperature
75°C
Constant exhaust temperature that is set for constant
temperature control on fan.
Fan stop temperature
65°C
When the exhaust temperature is lower than this value, the
fan is stopped.
Fan startup
temperature
75°C
When the exhaust temperature is higher than this value, the
fan is started.