Goodrive300-01A series VFD for air compressor
Function code description
-89-
5.4 Operating logic of blower oil pump
Dedicated function of the blower oil pump: RO terminal is enabled after the VFD start command is
received, the VFD starts after start delay time (P01.23) is reached and stops after the VFD stop
command is received. RO terminal closes output after corresponding switch-off delay time is reached.
For details about "RO switch-off delay" in the following figure, refer to P06 group function parameters,
and set the corresponding RO switch-off delay function code according to the current RO terminal.
Forward running signal
1
0
Time
Oil pump start/stop
1
0
Time
RO switch-off
delay
1
0
VFD start/stop
P01.23
Time
Содержание Goodrive300-01A Series
Страница 1: ......
Страница 175: ...6 6 0 0 1 0 0 5 5 3...