6.2 Fault contents and solutions of air compressor equipment
Abnormal state and solutions of air compressor equipment:
P19.13
State type
Possible cause
Solution
BIT0=1
Air filter blocked
Air filter is abnormal.
Check air filter after stop.
BIT1=1
Oil filter blocked
Oil filter is abnormal.
Check oil filter after stop.
BIT2=1
Separator blocked
Separator is abnormal.
Check the separator after
stop.
BIT3=1
Precision splitter
blocked
Precision splitter is
abnormal.
Check the precision splitter
after stop.
BIT8=1
Pressure pre-alarm
Actual voltage is
detected by P1 to be
larger than the
pre-alarm voltage set
by P18.17.
Check whether solenoid valve
is normal.
Check whether pressure
control parameters are set
correctly.
BIT9=1
Temperature
pre-alarm
Actual temperature
detected by PT1 is
higher than the
pre-alarm temperature
set by P18.19.
Check whether fan control
parameters are set correctly.
Whether the fan operates
normally.
Fan power is too small to
dissipate heat effectively.
Check whether there is
lubricating oil.
BIT10=1
Pressure alarm
Actual voltage detected
by P1 is larger than the
alarm voltage set by
P18.18.
Check whether solenoid valve
is normal.
Check whether pressure
control parameters are set
correctly.
BIT11=1
Temperature alarm
Actual temperature
detected by PT1 is
higher than the alarm
temperature set by
P18.20.
Check whether fan control
parameters are correct.
Whether fan operates
normally.
Fan power is too small to
dissipate heat effectively.
Check whether there is
lubricating oil.
BIT12=1 Pressure signal fault
The actual voltage is
detected by P1 to be
less than 1V.
Pressure detection sensor is
abnormal.
Pressure detection input P1
signal wire is disconnected.
Pressure signal interface does