Goodrive300-01A series VFD for air compressor
Function code description
-74-
Function
code
Name
Description
Default Modify
P19.10
Actual output power of
the motor
Display motor output power, it can be
calibrated by P18.22.
Range: 0.0
–6553.5kW
0.0kW
●
P19.11
Present pressure
Display
the
discharge
pressure
value
detected currently.
P05.32
P05.34
0
P18.04
P17.19
P1 input
voltage
Current
pressure Mpa
P19.11
P05.42
P05.44
0
P18.38
P17.21
P19.11
P2 input
voltage
Current
pressure
Mpa
P18.37=0
P18.37=1
Range: 0.00
–655.35Mpa
0.00Mpa
●
P19.12
Present temperature
Display the machine head temperature
detected currently.
P18.28
0
150
P17.20
-20
PT1 input
voltage
Current temperature
P19.12
P18.29
P18.32
0
150
P17.22
-20
PT2 input
voltage
Current temperature
P19.12
P18.33
P18.03=0
P18.03=1
Range: -20
–150°C
0°C
●
P19.13
Signal state 1
0000
–0xFFFF
BIT0: Air filter blockage signal
1: Fault; 0: Normal
BIT1: Oil filter blockage signal
0
●