Goodrive300-01A series VFD for air compressor
Function code description
-51-
P08 group Enhanced functions
Function
code
Name
Description
Default Modify
P08.15
Bus voltage
pre-protection function
0
–0x11Ones: Bus protection function
Tens: Low-frequency current protection
function
0x10
○
P08.16
Low-voltage protection
threshold
0.0V
–2000.0V
300.0V
○
P08.17
Overvoltage
pre-protection
threshold
0.0V
–2000.0V
780.0V
○
P08.18 Automatic restart delay 0.0
–6000.0s
60.0s
○
P08.19
Low-voltage frequency
limit running time
0.0
–6000.0s
60.0s
○
P08.20
High-frequency current
loop proportional gain
0
–20000
1000
○
P08.21
High-frequency current
loop integral time
0
–20000
1000
○
P08.23
High-frequency current
loop switching
frequency
0.0
–100.0% (max. output frequency P00.03)
100.0%
○
P08.24
Fan control enable
selection
0
–1
0: Enable fan control
1: Disable fan control
Note:
Applicable to 7.5
–15kW single-VFD
integrated machine only, used to control the
start/stop of a power-frequency fan.
0
○
P08.25
Keypad lock enable
0: Do not lock keypad
1: Allow to lock keypad
Lock: Press PRG key+DATA key
simultaneously
Unlock: Keep DATA key pressed down and
then click V key by three times.
0
○
P08.26
Maintenance timing
mode
0: No timing during sleep
1: Timing during sleep
0
○
P08.27
SM optimal mode
selection
0: Disable
It is applicable to the surface-mounted
synchronous motors. P02.21 (Direct-axis
inductance
of
SM
1)
and
P02.22
(Quadrature-axis inductance of SM 1) are
0
○