Goodrive300-01A series VFD for air compressor
Function code description
-63-
Function
code
Name
Description
Default Modify
P15.07
Auxiliary pressure
low protection point
0.00
–20.00MPa
When the auxiliary pressure protection is
enabled (P18.39=1), if the auxiliary pressure is
less than the value set in P15.07, the auxiliary
pressure too low fault is reported.
Note:
When the compressor is in the sleeping
state, the auxiliary pressure too low fault is not
judged.
0.00
○
P15.08
Dynamic password
0
–9999
Note:
The dynamic password is automatically
refreshed every power-on/every 8 hours/every
time a new P15.09 value is written.
0000
●
P15.09
Handshake
password
0
–9999
Note:
Handshake password (P15.09) is used to
open or close the handshake protocol.
0000
◎
P15.10
Handshake timeout
0
–65535s
Note:
If the handshake is still not successful
after the time set in P15.10 is reached, the
HAnd fault is reported, and no fault is reported
when P15.10 is set to 0.
20s
○
P15.11
Handshake state
0
–1
0: The handshake function is disabled.
1: The handshake function is enabled.
0
●
P15.12
Pressure decimal
places
0
–1
0: Two decimal places
1: Three decimal places
0
○
P17 group Status viewing
Function
code
Name
Description
Default Modify
P17.00
Setting frequency
0.00Hz
–P00.03
0.00Hz
●
P17.01
Output frequency
0.00Hz
–P00.03
0.00Hz
●
P17.02
Ramps reference
frequency
0.00Hz
–P00.03
0.00Hz
●
P17.03
Output voltage
0
–1200V
0V
●
P17.04
Output current
0.0
–3000.0A
0.0A
●
P17.05
Motor speed
0
–65535RPM
0 RPM
●
P17.06
Torque current
-3000.0
–3000.0A
0.0A
●
P17.07
Excitation current
-3000.0
–3000.0A
0.0A
●