Goodrive300-01A series VFD for air compressor
Function code description
-64-
Function
code
Name
Description
Default Modify
P17.08
Motor power
-300.0%
–300.0% (relative to rated motor
power)
0.0%
●
P17.09
Output torque
-250.0
–250.0%
0.0%
●
P17.10
Estimated motor
frequency
0.00
–P00.03
0.00Hz
●
P17.11
DC bus voltage
0.0
–2000.0V
0V
●
P17.12
Digital input terminal
state
0000
–00FF
0
●
P17.13
Digital output terminal
state
0000
–000F
0
●
P17.16
Master fault code
0
–43 (see P07.27–P07.32 for details)
0
●
P17.17
Reserved
0
–38
0
●
P17.19
P1-input voltage
Display analog input voltage value of P1-
channel,
2.00V
–10.00V corresponds to
4
–20mA; P05.32–P05.34 correspond to
pressure 0.0
–P18.04. If P1- input voltage is
larger than 9.8V or less than 1V, it indicates
pressure signal fault occurs.
Range: 0.00
–10.00V
0.00V
●
P17.20
PT1 input voltage
Display analog input voltage value of PT1
channel.
Under
air-compressor
mode,
connect
to
PT100
thermal
resistor
temperature sensor, different temperature
generates different resistor value, and
different resistor value corresponds to
different input voltages, therefore, the input
voltage
value
can
correspond
to
corresponding detection temperature. Input
voltage P18.28-P18.29 corresponds to -20°C
to +150°C.
Setting range: 0.00
–10.00V
0.00V
●
P17.21
P2- input voltage
Display analog input voltage value of P2-
channel,
2.00V
–10.00V
correspond
to
4
–20mA; P05.42–P05.44 correspond to
pressure 0.0
–P18.38. When the input voltage
of P2- is larger than 9.8V or less than 1V, it
indicates pressure signal fault occurs.
Setting range: 0.00
–10.00V
0.00V
●