Goodrive300-01A series VFD for air compressor
Communication protocol
-162-
Function
description
Address
definition
Data meaning
R/W
attribute
2010H
The set maintenance time of part 1;
Range: 0
–65535
W
2011H
The set maintenance time of part 2;
Range: 0
–65535
W
2012H
The set maintenance time of part 3;
Range: 0
–65535
W
2013H
The set maintenance time of part 4;
Range: 0
–65535
W
2014H
The set maintenance time of part 5;
Range: 0
–65535
W
2015H
Running time of part 1, 0
–65535
W
2016H
Running time of part 2, 0
–65535
W
2017H
Running time of part 3, 0
–65535
W
2018H
Running time of part 4, 0
–65535
W
2019H
Running time of part 5, 0
–65535
W
201AH
Running time of the device: 0
–65535
W
201BH
Start/stop command of power-frequency fan,
0
–3
W
VFD state word 1
2100H
0001H: In forward running
R
0002H: In reverse running
0003H: In stopping
0004H: In fault
0005H: VFD Poff state
0006H: VFD pre-exciting state
VFD state word 2
2101H
Bit0: =0: Not ready to run =1: Ready to run
Bi1
–2: =00: Motor 1 =01: Motor 2
=10: Motor 3 =11: Motor 4
Bit3: =0: Asynchronous motor
=1: Synchronous motor
Bit4: =0: Non-overload pre-alarm
=1: Overload pre-alarm
Bit5
– Bit6:
=00: Keypad control
=01: Terminal control
=10: communication control
R
VFD fault code
2102H
See fault type
R
VFD identification
code
2103H
GD300-01A-----0x012F
R
Содержание Goodrive300-01A Series
Страница 1: ......
Страница 175: ...6 6 0 0 1 0 0 5 5 3...