Goodrive300-01A series VFD for air compressor
Function code description
-45-
P06 group Output terminals
Function
code
Name
Description
Default Modify
P06.01
Reserved
0: Invalid
1: In running
2: In forward running
3: In reverse running
4: In jogging
5: VFD fault
6
–11: Reserved
12: Ready to run
13: In pre-exciting
14
–19: Reserved
20: External fault is valid
21
–22: Reserved
23: Modbus communication virtual terminal
output
24
–25: Reserved
26: Function only for oil pump (blower)
27: Fan start/stop control
28: Solenoid valve control output
29: Cooling fan control of main motor
30: Reserved
0
○
P06.02
RO3 output selection
0
○
P06.03
RO1 output selection
0
○
P06.04
RO2 output selection
0
○
P06.05
Output terminal
polarity selection
This function code is used to set the output
terminal polarity.
When the bit is set to 0, output terminal
polarity is positive;
When the bit is set to 1, output terminal
polarity is negative.
BIT3
BIT2
BIT1
BIT0
RO2
RO1
RO3
Reserved
Setting range: 0
–0xF
0
○
P06.08
RO3 switch-on delay 0.000
–50.000s
0.000s
○
P06.09
RO3 switch-off delay 0.000
–50.000s
0.000s
○
P06.10
RO1 switch-on delay 0.000
–50.000s
0.000s
○
P06.11
RO1 switch-off delay 0.000
–50.000s
0.000s
○
P06.12
RO2 switch-on delay 0.000
–50.000s
0.000s
○
P06.13
RO2 switch-off delay 0.000
–50.000s
0.000s
○
P06.14
AO1 output selection
0: Running frequency
1: Set frequency
24
○