Goodrive300-01A series VFD for air compressor
Function code description
-77-
Function
code
Name
Description
Default Modify
P19.19
Output value of
temperature PID
Display the output value of temperature PID
regulation
of
machine
head,
100%
corresponds to P00.03 [the max. output
frequency of the fan].
Setting range: 0.00
–100.00%
0.00%
●
P19.20
Present auxiliary
pressure
Display the auxiliary pressure value detected
at present.
P05.42
P05.44
0
P18.38
P17.21
P19.20
P2 input
voltage
Present
auxiliary
pressure Mpa
P05.32
P05.34
0
P18.04
P17.19
P1 input
voltage
Present auxiliary
pressure Mpa
P19.20
P18.37=0
P18.37=1
Range: 0.00
–655.35Mpa
0.00Mpa
●
P19.21
Present auxiliary
temperature
Display the auxiliary temperature value
detected at present.
P18.28
0
150
P17.20
-20
PT1 input
voltage
Present auxiliary
temperature
P19.21
P18.29
P18.32
0
150
P17.22
-20
PT2 input
voltage
Present auxiliary
temperature
P19.21
P18.33
P18.03=0
P18.03=1
Range: -20
–150°C
0°C
●
Содержание Goodrive300-01A Series
Страница 1: ......
Страница 175: ...6 6 0 0 1 0 0 5 5 3...