Goodrive300-01A series VFD for air compressor
Function code description
-36-
Function
code
Name
Description
Default Modify
Plot controller)
4: Start/stop the VFD with one click in terminal
mode (compatible with the Plot controller)
5
–6: Reserved
7: Customer 1 parameter 1
8: Customer 1 parameter 2
9: Customer 2 parameter
10: Customer 3 parameter
Note:
Though restoring to default values is
enabled, the motor parameters in P02 group
remain unchanged; P05.38, P05.40, P05.48,
P05.50, P18.04, P18.28, P18.29, P18.32,
P18.33, P18.38, P21.04, P21.05, and P21.06
also remain unchanged.
P01 group Start and stop control
Function
code
Name
Description
Default Modify
P01.01
Starting frequency of
direct startup
0.00
–50.00Hz
0.50Hz
◎
P01.08
Stop mode selection
0: Decelerate to stop
1: Coast to stop
0
○
P01.15
Stop speed
0.00
–100.00Hz
0.50Hz
◎
P01.16
Stop speed detection
mode
0: Detect as per the set speed value (judge
the ramps frequency)
1: Detect as per the speed feedback value
(valid for vector control only)
1
◎
P01.17
Feedback speed
detection time
0.00
–100.00 s (valid only when P01.16=1)
0.50s
◎
P01.23
Start delay
0.0
–60.0 s
0.0s
○
P02 group Motor 1 parameters
Function
code
Name
Description
Default Modify
P02.00
Type of motor 1
0: AM
1: SM
0
◎
P02.01
Rated power of AM 1 0.1
–3000.0kW
Depend
on model
◎
P02.02
Rated frequency of AM
1
0.01Hz
–P00.03 (max. frequency)
50.00Hz
◎