Goodrive300-01A series VFD for air compressor
Function code description
-40-
Function
code
Name
Description
Default Modify
P03.21
Keypad setting of the
upper limit of brake
torque
0.0
–300.0% (rated motor current)
180.0%
○
P03.22
Flux-weakening
coefficient in constant
power area
0.1
–2.0
0.3
○
P03.23
Min. flux-weakening
point in constant power
area
10%
–100%
20%
○
P03.24
Max. voltage limit
0.0
–120.0%
100.0%
○
P03.25
Pre-excitation time
0.000
–10.000s
0.300s
○
P03.26
Flux-weakening
proportional gain
0
–8000
300
○
P03.27
Vector control speed
display selection
0: Display as per actual value
1: Display as per the set value
0
○
P03.28
IF starting current
0
–100.0% (rated current of the motor)
60.0%
○
P04 group Space voltage vector control
Function
code
Name
Description
Default Modify
P04.00
V/F curve setting of
motor 1
0: Straight V/F curve
1: Multi-point V/F curve
2: Torque step-down V/F curve (1.3 order)
3: Torque step-down V/F curve (1.7 order)
4: Torque step-down V/F curve (2.0 order)
5: Reserved
0
◎
P04.01
Torque elevation of
motor 1
0.0%: (automatic) 0.1%
–10.0%
0.0%
○
P04.02
Torque elevation
cut-off of motor 1
0.0%
–50.0% (relative to rated frequency of
motor 1)
20.0%
○
P04.03
V/F frequency point 1
of motor 1
0.00Hz
–P04.05
0.00Hz
○
P04.04
V/F voltage point 1 of
motor 1
0.0%
–110.0% (rated voltage of motor 1)
00.0%
○
P04.05
V/F frequency point 2
of motor 1
P04.03
–P04.07
00.00Hz
○
P04.06
V/F voltage point 2 of
motor 1
0.0%
–110.0% (rated voltage of motor 1)
00.0%
○
P04.07 V/F frequency point 3 P04.05
–P02.02 (rated frequency of motor 1)
00.00Hz
○