Goodrive300-01A series VFD for air compressor
Function code description
-60-
P13 group SM control
Function
code
Name
Description
Default Modify
P13.00
Pull-in current
reduction coefficient
0.0
–100.0%
50.0%
○
P13.01
Initial magnetic pole
detection mode
0: Do not detection
1: High frequency superposition (reserved)
2: Pulse superposition (reserved)
0
◎
P13.02
Pull-in current 1
0.0%
–100.0% rated motor current
20.0%
○
P13.03
Pull-in current 2
0.0%
–100.0% rated motor current
10.0%
○
P13.04
Switching frequency of
pull-in current
0.00Hz
–P00.03 (max. frequency)
30.00Hz
○
P13.05
High-frequency
superposing frequency
(reserved)
200Hz
–1000Hz
500Hz
◎
P13.06
High frequency
superposing voltage
0.0
–300.0% of the rated motor voltage
40.0%
◎
P13.08
Control parameter 1 0
–FFFF
0x120
○
P13.09
Control parameter 2 0
–300.00
5.00
○
P13.11
Maladjustment
detection time
Adjust the responsiveness of the function
used to prevent maladjustment. Increase the
value of P13.11 if load inertia is too large,
however, the response speed will be impacted
if the value is increased.
Setting range: 0.0
–10.0s
0.5s
○
P13.12
High-frequency
compensation
coefficient
When the motor runs at rated speed, this
parameter is valid. If motor vibration occurs,
adjust this parameter properly.
Setting range: 0.0
–100.0%
50.0%
○
P14 group Serial communication
Function
code
Name
Description
Default Modify
P14.00
Local communication
address
1
–247, 0 is broadcast address
2
○
P14.01
Communication baud
rated setup
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
4
○