12.1 Standard Model
12-15
SP
EC
IF
IC
AT
IO
N
S
Chap 1
2
■
Standard-model, Three-phase 400 V (460 V) class series (HHD-mode: 5.5 kW to 37 kW)
Item
Specifications
Type (FRN_ _ _ _E2S-4
)
0022
0029
0037
0044
0059
0072
0085
0105
Nominal applied motor (kW) [HP]
(Output rating)
*1
5.5
[7.5]
7.5
[10]
11
[15]
15
[20]
18.5
[25]
22
[30]
30
[40]
37
[50]
O
utput r
ati
ngs
Rated capacity (kVA)
*2
9.9
[10]
14
[14]
18
[19]
23
[24]
30
[31]
34
[36]
46
[48]
57
[60]
Rated voltage (V)
*
3
Three-phase 380 to 480 V (with AVR function)
Rated current (A)
*
4
13
18
24
30
39
45
60
75
Overload capability
150%-1 min, 200%-0.5 s
Input powe
r
Voltage, frequency
Three-phase 380 to 480 V, 50/60 Hz
Allowable voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*6
,
Frequency: +5 to -5%
Rated input current
*7
(w/o DCR) (A)
17.3
23.2
33
43.8
52.3
60.6
77.9
94.3
(with DCR) (A)
10.6
14.4
21.1
28.8
35.5
42.2
57.0
68.5
Required capacity
(with DCR) (kVA)
*8
7.3
10
15
20
25
29
39
47
B
rak
ing
Torque (%)
*9
20%
10% to 15%
DC braking
Braking starting frequency: 0.0 to 60.0 Hz, Braking time: 0.0 to 30.0 s,
Braking level: 0 to 100%
Braking transistor
Built-in as standard
Minimum resistance value (
Ω
)
80
60
40
34.4
16
-
Braking resistor
Separately mounted option
DC reactor (DCR)
Separately mounted option
Applicable safety standards
IEC/EN61800-5-1: 2007
Enclosure (IEC60529)
IP20, UL open type
Cooling method
Fan cooling
Weight / Mass (kg) [lbs]
5.0
[11]
5.0
[11]
8.0
[18]
9.0
[20]
9.5
[21]
10
[22]
25
[55]
26
[57]
Note: A box (
) in the above table replaces GA, GB or C depending on the model.
*1 Fuji 4-pole standard motor
*2 Rated capacity is calculated assuming the rated output voltage as 440 V (460 V).
*3 Output voltage cannot exceed the power supply voltage.
*4 Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec of type FRN0002
E2■
-4
to FRN0012
E2■
-4
: 8 kHz,
HHD spec of type FRN0022
E2■
-4
to FRN0168
E2■
-4
: 10 kHz,
HHD spec of type FRN0203
E2■
-4
to FRN0590
E2■
-4
: 6 kHz,
If reduction is necessary, for details, refer to Figure 10.4-1 in Chapter 10 “10.4.2 Guideline for selecting
inverter drive mode and capacity.”
*6
67
×
(V)
voltage
average
phase
-
Three
(V)
voltage
Min.
-
(V)
voltage
Max.
=
(%)
unbalance
Voltage
(IEC 61800-3)
If the unbalance ratio is 2% to 3%, use an optional AC reactor (ACR).
*7 This specification is an estimated value to be applied when the power supply capacity is 500 kVA (Inverter
capacity × 10 when the capacity exceeds 50 kVA) and the power supply with %X = 5% is connected. When
applying with motors of 75 kW (100 HP) or above, a DC reactor (DCR) should be used.
*8 This specification applies when a DC reactor (DCR) is used.
*9 Average braking torque for the motor running alone. It depends on the efficiency of the motor.
Содержание FRENIC-Ace series
Страница 20: ......
Страница 32: ......
Страница 92: ......
Страница 94: ......
Страница 452: ......
Страница 490: ......
Страница 504: ......
Страница 506: ...8 2 Frequency Setting Section 8 2 8 2 Frequency Setting Section Figure 8 2 1 Frequency Setting Section Block Diagram...
Страница 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Страница 514: ...8 6 Control Section 8 10 3 With speed sensor Figure 8 6 3 V f Control with speed sensor Section Block Diagram...
Страница 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Страница 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Страница 582: ......
Страница 646: ...11 9 Power Regenerative PWM Converters RHC Series 11 42 11 9 5 External dimensions PWM converter Boosting reactor...
Страница 649: ...11 9 Power Regenerative PWM Converters RHC Series 11 45 SELECTING PERIPHERAL EQUIPMENT Chap 11 Charging resistor Fuse...
Страница 664: ...11 15 External Cooling Fan Attachments 11 60...
Страница 690: ......
Страница 692: ......
Страница 720: ......
Страница 738: ......
Страница 787: ......